23
2537376-01-04/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTP/CTA-L1/2-BR
EN
10.6. Connector assignment of safety switches CTP/CTA-…-BR-…-SAB-…
with plug connectors 2 x M12
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring of
connecting cable
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
FI1B
Enable input, channel B
WH
X 1.2
UB
Electronics operating voltage, 24 V DC
BN
X 1.3
FO1A
Safety output, channel A
GN
X 1.4
FO1B
Safety output, channel B
YE
X 1.5
OL/C
Guard lock monitoring output/communication
GY
X 1.6
FI1A
Enable input, channel A
PK
X 1.7
0VUB
Electronics operating voltage, 0 V DC
BU
X 1.8
RST
Reset input
RD
X 2.1
IMM
Solenoid operating voltage, 0 V DC
BN
X 2.2
OD
Door position monitoring output
WH
X 2.3
OI
Diagnostic monitoring output
BU
X 2.4
IMP
Solenoid operating voltage, 24 V DC
BK
X 2.5
-
n.c.
GY
1) Only for standard EUCHNER connecting cable.
10.7. Connector assignment of safety switches CTP/CTA-...-BR-...-AZDE-SAB-...
with plug connectors 2 x M12
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring of
connecting cable
1)
2 x M12
X2.5
X1.8
X1.5
X1.6
X1.7
X1.2
X2.4
X2.3
X2.1
X2.2
X1.4
X1.3
X1.1
X 1.1
FI1B
Enable input, channel B
WH
X 1.2
UB
Electronics operating voltage, 24 V DC
BN
X 1.3
FO1A
Safety output, channel A
GN
X 1.4
FO1B
Safety output, channel B
YE
X 1.5
OD/C
Door position monitoring output/communication
GY
X 1.6
FI1A
Enable input, channel A
PK
X 1.7
0V
Electronics and solenoid operating voltage, 0 V DC
BU
X 1.8
UA
Solenoid (auxiliary) voltage, 24 V DC
(connected internally to UB)
RD
X 2.1
S1.A1
Emergency stop (channel A contact 1)
BN
X 2.2
S1.B1
Emergency stop (channel B contact 1)
WH
X 2.3
-
n.c.
BU
X 2.4
S1.A2
Emergency stop (channel A contact 2)
BK
X 2.5
S1.B2
Emergency stop (channel B contact 2)
GY
1) Only for standard EUCHNER connecting cable.
10.8. Connector assignment of safety switches CTP/CTA-…-BR-…-SA-…
with plug connector M12, 8-pin
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring of
connecting cable
1)
1 x M12
8
5
6
7
2
4
3
1
1
FI1B
Enable input, channel B
WH
2
UB
Electronics operating voltage, 24 V DC
BN
3
FO1A
Safety output, channel A
GN
4
FO1B
Safety output, channel B
YE
5
OD/C
Door position monitoring output/communication
GY
6
FI1A
Enable input, channel A
PK
7
0V
Electronics and solenoid operating voltage, 0 V DC
BU
8
IMP
Solenoid operating voltage, 24 V DC
RD
1) Only for standard EUCHNER connecting cable.