Functional description 

General 

The CET3 is a guard locking device according to EN ISO 14119 using the closed-circuit current principle. In this example 3 CET3-

AR are connected in series. The two safe outputs of the last CET3 are connected to a PNOZ s5 safety relay. 

Connections 

Designation 

Function 

Use in this example 

OA, OB 

Safety outputs. HIGH when the safety guard is 

closed and locked. 

Switch-off of at least one of the outputs leads to a direct 
switch-off of the safety contacts (13 – 14, 23 – 24, …) of 

the safety relay PNOZ s5. 
Important: The actual shutdown of the energy which is 

causing a hazard in a machine is not shown in the example 

and must be supplemented. 

IA, IB 

Inputs for series connection of AR devices from 

EUCHNER 

At B3 connected to 24V DC. 
At B2 and B1 connected to OA and OB of the previous 

device. 

+UCM,  
0V (UCM) 

Control input for guard locking solenoid. Connect 

guard locking to 24 V DC to open. 

Activated by switches S1, S3 and S4. 
Important: According to EN ISO 14119, it shall be ensured 

that the hazard caused by a machine has disappeared 

before the guard locking can be released. 

OUT 

Monitoring output. HIGH when outputs OA and OB 

are switched on (safety guard closed and locked). 

Function is not used 

OUTD 

Door monitoring output. HIGH when the actuator is 
within the operating distance and the CET is ready 
for controlling guard locking (safety guard closed). 

Function is not used 

LED1 

Input for controlling the installed red LED. 

Function is not used. 

RST 

Input for resetting the switch 

Activated via switch S5. All CET3 connected in series must 

be reset simultaneously. Refer to the section “AR safety 

switches connected in series”

Teach-in input 

Only for ID No. 109401, 113139, 113965, 114508, 

114512. 
The corresponding input must be connected to 24 V DC for 

actuator teach-in (for this purpose, see the operating 

instructions

1)

). 

Important: for teach-in operation terminal 0V (UCM) has to 

be connected to 0V not to a different potential or to an 

output. 
The input must be unconnected during operation. 

--- 

Input not connected 

Only for ID No. 112921, 113958, 114090 

This input must always be connected to GND. 

1) You can find the current operating instructions on the Internet at www.euchner.de. Simply enter the order number into the 

search field.

 

 

 

Содержание CET3-AR Series

Страница 1: ...CHNER 2 Other 2 Functional description 3 General 3 Connections 3 Safety assessment 4 Principle circuit diagram 5 AR safety switches connected in series 7 Usage of the Reset input 7 Teaching in actuators 7 Setting of the operating mode selector switch mode 8 Automatic manual start without short circuit detection 8 Monitored start rising edge without short circuit detection 8 Monitored start falling...

Страница 2: ... no item designation Safety switches with guard locking and guard locking monitoring with transponder technology 109401 CET3 AR CRA AH 50X SG 109401 112921 CET3 AR CRA CH 50F SG C2333 112921 113139 CET3 AR CRA AH 50X SG C2290 113139 113958 CET3 AR CRA CH 50F SG C2357 113958 113965 CET3 AR CRA AH 50F SG 113965 114090 CET3 AR CDA CH 50X SG 114090 114508 CET3 AR CRA AH 50F SG C2333 114508 114512 CET3...

Страница 3: ...ortant According to EN ISO 14119 it shall be ensured that the hazard caused by a machine has disappeared before the guard locking can be released OUT Monitoring output HIGH when outputs OA and OB are switched on safety guard closed and locked Function is not used OUTD Door monitoring output HIGH when the actuator is within the operating distance and the CET is ready for controlling guard locking s...

Страница 4: ...Z s5 Therefore PL e in accordance with EN ISO 13849 1 can be achieved for locking mechanism position monitoring of guard locking of the CET3 Series connection of three CET3 devices does not reduce the achievable PL A safety assessment for control of guard locking is not part of this example and must be supplemented for the respective machine by the design engineer in accordance with the risk asses...

Страница 5: ...ical modifications no responsibility is accepted for the accuracy of this information EUCHNER 2016 AP000152 05_03 16 Page 5 of 10 Principle circuit diagram In the example Automatic Reset of the PNOZ s5 is used Figure 1 ...

Страница 6: ...Subject to technical modifications no responsibility is accepted for the accuracy of this information EUCHNER 2016 AP000152 05_03 16 Page 6 of 10 Figure 2 ...

Страница 7: ...each in input J proceed as follows 1 Open the safety door on which the switch or actuator is to be replaced 2 Mount the new switch or actuator and close all safety doors in the chain 3 Actuate the reset for at least 3 s 24 V on RST 4 On the safety switch that is positioned at a new actuator the green LED flashes at approx 1 Hz and the actuator is taught in This happens for approx 1 minute do not s...

Страница 8: ...tly with a CET3 Automatic manual start without short circuit detection Operating mode selector switch mode Automatic manual start Without short circuit detection Monitored start rising edge without short circuit detection Operating mode selector switch mode Monitored start rising edge Without short circuit detection Monitored start falling edge without short circuit detection Operating mode select...

Страница 9: ...ity is accepted for the accuracy of this information EUCHNER 2016 AP000152 05_03 16 Page 9 of 10 Setting of the Reset for PNOZ s5 Only with the following settings does the safety relay PNOZ s5 operate correctly with a CET3 Manual Reset Automatic Reset ...

Страница 10: ...only as assistance for the considerations about safety measures The design engineer of a machine installation is obligated to assess the safety technology himself The examples must not be used for assessment because only a small excerpt of a complete safety function was considered in terms of safety engineering here In order to be able to use the safety switch applications correctly on safety guar...

Отзывы: