![EUCHNER CET.-AR Series Скачать руководство пользователя страница 25](http://html.mh-extra.com/html/euchner/cet-ar-series/cet-ar-series_operating-instructions-manual_2434843025.webp)
25
2110788-13-03/20 (Translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CET.-AR-…
EN
10.7.2. Version with door monitoring output (CET3/4)
Wiring diagram E
Plug connector
(view of connection side)
Pin
Designation
Function
Conductor coloring
of connecting
cable
1)
M23 (RC18)
With shield
spring
18
19
15
12
11
9
5
4
3
2
1
17
16
14
13
6
10
8
7
1
U
CM
Operating voltage of guard locking solenoid, 24 V DC
VT
2
IA
Enable input for channel A
RD
3
IB
Enable input for channel B
GY
4
OA
Safety output channel A
RD/BU
5
OB
Safety output channel B
GN
6
U
B
Operating voltage of AR electronics, 24 V DC
BU
7
RST
Reset input
GY/PK
8
OUT D
Door monitoring output
GN/WH
9
-
n.c.
YE/WH
10
OUT
Monitoring output
GY/WH
11
-
n.c.
BK
12
FE
Function earth:
This connection must be connected to 0 V.
GN/YE
13
J
Version with teach-in input:
To teach-in a new actuator, connect to 24 V DC; leave open in normal
operation.
2)
PK
Y
Version with feedback loop:
If the feedback loop is not used, connect to 24 V DC.
-
Version without feedback loop and without teach-in input:
This connection must be connected to 0 V.
14
-
n.c.
BN/GY
15
LED 1
LED 1 red, freely configurable, 24 V DC
BN/YE
16
LED 2
LED 2 green, freely configurable, 24 V DC
BN/GN
17
-
n.c.
WH
18
0 V U
CM
Operating voltage of guard locking solenoid, 0 V
YE
19
0 V U
B
Operating voltage of AR electronics, 0 V
BN
1) Only for standard EUCHNER connecting cable.
2) With dual-channel solenoid control, do not connect to 0 V U
B