13. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
13.1. Technical data for safety switch CET.-AP-C..-AH-…
Parameter
Value
Unit
min.
typ.
max.
General
Material, ramp
Stainless steel
Material, safety switch housing
Die-cast aluminum
Installation position
Any (recommendation: switch head downward)
Degree of protection
with plug connector M12
IP 67
with plug connector M23
(RC18)
IP65/IP67
Safety class
III
Degree of contamination
3
Mechanical life
1 x 10
6
operating cycles
Ambient temperature at U
B
-20
-
+55
°C
Actuator approach speed, max.
20
m/min
Locking force F
max
6,500
N
Locking force F
Zh
in acc. with test principles GS-ET-19
F
Zh
= F
max
/1.3 = 5,000
N
Weight
Approx. 1.0
kg
Degrees of freedom (actuator in recess) X, Y, Z
X and Y: ± 5; Z: ± 4
mm
Connection type (depending on version)
2 plug connectors M12, 5-pin, 1 plug connector M12, 8-pin,
1 plug connector M23 (RC18), 19-pin
Operating voltage U
B
(reverse polarity protected, regulated,
residual ripple < 5%)
1)
24 ± 15% (PELV)
V DC
Current consumption I
B
80
mA
External fuse (operating voltage U
B
)
0.5
-
3
A
External fuse (solenoid operating voltage U
CM
)
0.5
-
2
A
Rated insulation voltage U
i
-
-
75
V
Conditional short-circuit current
100
A
Resilience to vibration
Acc. to EN 60947-5-2
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay
-
-
1
s
Risk time
-
-
400
ms
Switch-on time
-
-
500
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
-
-
0.3
2)
ms
Safety outputs
OA/OB
Semiconductor outputs (p-switching, short circuit-proof)
- Output voltage U
OA
/U
OB
3)
V DC
HIGH
U
OA
/U
OB
U
B
- 1.5
-
U
B
LOW
U
OA
/U
OB
0
-
1
Switching current per safety output
1
-
200
mA
Utilization category according to EN 60947-5-2
DC-13 24 V 200 mA
Caution: outputs must be protected with a free-wheeling diode in case of inductive loads
Switching frequency
0.5
Hz
Monitoring outputs
OUT and OUT D (optional)
(p-switching, short circuit-proof)
Output voltage
0.8 x U
B
-
U
B
V DC
Max. load
-
-
50
mA
Teach-in input J or feedback loop input Y
HIGH
15
-
26.4
V
LOW
0
-
1
Solenoid
Solenoid operating voltage U
CM
(reverse polarity protected,
regulated, residual ripple < 5%)
1)
DC 24 V +10%/-15%
Solenoid current consumption I
CM
480
mA
Power consumption
Max. 12
W
Duty cycle
100
%
Reliability values acc. to EN ISO 13849-1
Head downward or horizontal
Head upward
Mission time
20
20
years
Monitoring of guard locking and the guard position
Head downward or horizontal
Head upward
Category
4
3
Performance Level (PL)
e
e
PFH
D
3.1 x 10
-9
/h
4.29 x 10
-8
/h
Activation of guard locking
Category
Depends on external control
Performance Level (PL)
PFH
D
1) The device tolerates voltage interruptions of up to 5 ms.
2) Applies to a load with C < 30 nF and R < 20 kohm
3) Values at a switching current of 50 mA without taking into account the cable lengths.