![EUCHNER CES-I-AP-C04 Series Скачать руководство пользователя страница 27](http://html.mh-extra.com/html/euchner/ces-i-ap-c04-series/ces-i-ap-c04-series_operating-instructions-manual_2434836027.webp)
27
2115159-13-03/20 (Translation of the original operating instructions)
Operating Instructions
Non-Contact Safety Switch CES-I-AP-.-C04/C14-…
EN
12.5. Technical data for actuator CES-A-BDN-06
Parameter
Value
Unit
min.
typ.
max.
Housing material
Macromelt PA-based plastic
Dimensions
26 x
∅
6
mm
Weight
0.005
kg
Ambient temperature
- 40
-
+ 70
°C
Degree of protection acc. to EN IEC 60529
IP67
Installation position
Active face opposite read head
Power supply
Inductive via read head
12.5.1. Dimension drawing
Installation options
26
0
+0,5
Ø
30
* min.
30 *
30 *
6,1
0
+0,1
6
* Metal-free zone
Operating distance
C
A
Approach
direction
CAUTION
Ì
Do not mount at temperatures below 0 °C.
Ì
The actuator can be damaged during mounting.
12.5.2. Operating distances
Actuating range for center offset m = 0
Installation position
Parameter
Value
Unit
A
min.
typ.
max.
Operating distance
-
19
-
mm
Assured operating distance s
ao 1)
14
-
-
Switching hysteresis
1)
-
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) The values apply only to surface installation of the actuator in metal
Installation position
Parameter
Value
Unit
C
min.
typ.
max.
Operating distance
-
15
-
mm
Assured operating distance s
ao 1)
10
-
-
Switching hysteresis
1)
-
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) The values apply only to surface installation of the actuator in metal