Operating Instructions
Non-Contact Safety Switch CES-I-AP-.-C04/C14-…
20
(Translation of the original operating instructions) 2115159-13-03/20
12. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
12.1. Technical data for safety switch CES-I-AP-.-C04-…
Parameter
Value
Unit
min.
typ.
max.
Housing material
PBT plastic
Dimensions
42 x 25 x 18
Weight (device without connecting cable)
0.04
kg
Ambient temperature at U
B
= DC 24 V
- 25
-
+ 65
°C
Storage temperature
- 40
-
+ 70
Degree of protection
IP67
IP69K (only version with flying lead and version with plug connector M8 and mating connector
with the same degree of protection)
Safety class
III
Degree of contamination
3
Installation orientation
Any
Mounting method
Non-flush
Connection
- Plug connector M8, 4-pin or
- Connecting cable PUR, 0.25 mm², with plug connector M12, 5-pin, or
- Connecting cable PUR with flying lead, 5 x 0.25 mm²
Operating voltage U
B
(regulated, residual ripple < 5%)
24 ± 15% (PELV)
V DC
Current consumption
35
mA
External fuse
(operating voltage)
0.25
-
8
A
Safety outputs FO1A/FO1B
Semiconductor outputs, p-switching, short circuit-proof
- Output voltage U(FO1A)/U(FO1B)
1)
HIGH
U(FO1A)
U
B
-1.5
-
U
B
V DC
HIGH
U(FO1B)
LOW
U(FO1A)/U(FO1B)
0
1
Switching current per safety output
1
-
150
mA
Utilization category acc. to EN IEC 60947-5-2
DC-13 24 V 150 mA
Caution: Outputs must be protected by a free-wheeling diode in the case of inductive loads.
Off-state current I
r
2)
≤ 0.25
mA
Monitoring output DIA
1)
p-switching, short circuit-proof
- Output voltage
0.8 x U
B
-
U
B
V DC
- Max. load
-
-
50
mA
Rated insulation voltage U
i
-
-
300
V
Rated impulse withstand voltage U
imp
-
-
1.5
kV
Resilience to vibration
Acc. to EN IEC 60947-5-2
Switching frequency
-
-
1
Hz
Repeat accuracy R
acc. to EN IEC 60947-5-2
≤
10
%
EMC protection requirements
Acc. to EN IEC 60947-5-3
Ready delay
-
0.5
-
s
Risk time
-
-
260
ms
Turn-on time
-
-
300
ms
Discrepancy time
-
-
10
ms
Test-pulse duration
0.3
3)
ms
Test-pulse interval
100
ms
Reliability values acc. to EN ISO 13849-1
Category
4
Performance Level
PL e
PFH
D
4.1 x 10
-9
Mission time
20
years
1) Values at a switching current of 50 mA without taking into account the cable length.