System Manual Safety Switch CES-AH-C03-AH-SM
15
System status table
Operating mode
Actuator/
door position
Safety outputs
LA and LB
LED
indicator output
State
ST
ATE (gr
een)
DIA (r
ed)
Self-test
X
off
10 Hz
(3 s)
Self-test after power up
Normal operation
closed
on
Normal operation, door closed
open
off
1 x
Normal operation, door open
Teach-in standby
open
off
3 x
Door open, unit is ready for teach-in for another actuator (only short time after power-up)
Setup
closed
off
1 Hz
Teach-in operation
X
off
Positive acknowledgement after acknowledgement of teach-in operation
Fault display
X
off
x
Overload (e.g. short circuit on a safety output)
X
off
3 x
Over-temperature
X
off
4 x
Output fault (e.g. fault on a switching element)
X
off
5 x
Internal fault (e.g. component faulty, data fault)
Key to symbols
LED not illuminated
LED illuminated
10 Hz (8 s)
LED flashes for 8 seconds at 10 Hz
3 x
LED flashes three times
X
Any state
Important!
If you do not find the displayed device status in the System status table, this
indicates an internal device fault. In this case, you should contact the manufac-
turer.