System Manual Safety Switch CES-AH-C03-AH-SM
11
Connection cables and plug connectors
Caution!
Risk of damage to equipment or malfunctions as a result of incorrect connec-
tion cables.
Use EUCHNER connectors.
If other connection components are used, the following recommendations
apply. EUCHNER provides no warranty for safe function in case of failure to
comply with these requirements.
The maximum cable length should not exceed 50 m.
Recommended connection cable
:
e.g. LiYY 7 x 1mm²,
Ölflex classic 400P 7 x 0.75
Mating connector for the evaluation unit
:
EUCHNER M3, 9-pin, cable cross-section max. 1 mm² order no. 106 597
Alternative e.g.
Coninvers order no. RC-09S1N11600, cable cross-section max. 1 mm²
Important!
It is imperative you use the original tools from the connector manufacturer for as-
sembly and follow the assembly instructions from the connector manufacturer.
Connector assignment
1
2
3
4
5
9
6
7
8
Figure 1: Connector assignment safety switch CES-AH-C03-AH-SM
Pin
Designation
Description
1
NC
Not used *
Start
Start input
3
LA
Safety output, channel 1
4
+LA
Input for channel 1
5
+LB
Input for channel
6
LB
Safety output, channel
7
UB
Power supply, DC 4 V
8
0 V
Ground, DC 0 V
9
NC
Not used *
* The unused connection pins are not allowed to be connected by the user!
View of connection side