(translation of the original operating instructions) 2084606-19-09/17
Technical data
Parameter
Value
Unit
min.
typ.
max.
Housing material
Fortron, reinforced thermoplastic, fully encapsulated
Dimensions
42 x 25 x 12
mm
Weight (incl. 10 m cable)
0.3
kg
Ambient temperature
-25
-
+70
°C
Degree of protection
IP 67/IP 69K
Installation position
Any
Method of operation
Inductive
Power supply
Via evaluation unit
In combination with actuator CES-A-BBA on evaluation unit CES-A-AEA-…
Assured switch-off distance S
ar
-
-
32
mm
Operating distance for center offset m = 0
1)
- Switch-on distance
-
15
-
- Assured switch-on distance S
ao
10
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
3
-
In combination with actuator CES-A-BDA on evaluation unit CES-A-AEA-…
Assured switch-off distance S
ar
-
-
33
mm
Operating distance for center offset m = 0
2)
- Switch-on distance
-
16
-
- Assured switch-on distance S
ao
11
-
-
- Switching hysteresis
0.5
2
-
Minimum distance s for side approach direction
-
4
-
Connection cable
Hard-wired encapsulated connection cable, with crimped ferrules
PVC,
∅
4.6 mm
PUR,
∅
4.8 mm, suitable for drag chain
Cable length
-
-
25
m
1) These values apply to surface installation of the read head and the actuator.
2) These values apply to non-metallic surrounding material. Other materials on request.