Operating Instructions
Non-Contact Safety Switch CES-I-AS2A-C04
18
(Translation of the original operating instructions) 2120544-07-07/20
11.4. Technical data for actuator CES-A-BDN-06
Parameter
Value
Unit
min.
typ.
max.
Housing material
Macromelt PA-based plastic
Dimensions
26 x
∅
6
mm
Weight
0.005
kg
Ambient temperature
- 40
-
+ 70
°C
Degree of protection
IP67 / IP69K
1)
Installation orientation
Active face opposite read head
Power supply
Inductive via read head
1) With flush installation.
11.4.1. Dimension drawing
Installation options
26
0
+0,5
Ø
30
* min.
30 *
30 *
6,1
0
+0,1
6
* Metal-free zone
Operating distance
C
A
Approach
direction
CAUTION
Ì
Do not mount at temperatures below 0 °C.
Ì
The actuator can be damaged during mounting.
11.4.2. Operating distances
Actuating range for center offset m = 0
Approach direction
Parameter
Value
Unit
A
min.
typ.
max.
Operating distance
-
19
-
mm
Assured operating distance s
ao 1)
14
-
-
Switching hysteresis
1)
-
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) The values apply to surface mounting of the actuator.
Approach direction
Parameter
Value
Unit
C
min.
typ.
max.
Operating distance
-
15
-
mm
Assured operating distance s
ao 1)
10
-
-
Switching hysteresis
1)
-
2
-
Assured release distance s
ar
- in x/z direction
- in y direction
-
-
-
-
40
60
1) The values apply to surface mounting of the actuator.