background image

Operating Instructions

Safety Switches GP...

6

Subject to technical modifications; no r

esponsibility is accepted for the accuracy of this information.

 

 

© EUCHNER GmbH + Co. KG

 

2090205

-08

-04/18 (translation of the original operating instructions)

Figure 3:  Switching elements and switching functions

Version 

Switching contacts

GP.-538H… 

2 NC contacts

GP.-2121H… 

4 NC contacts

GP.-2131H… 

3 NC co 

 

1 NO contact

GP.-3131H… 

2 NC co 

 

2 NO contacts

34

42

22
12

12

22

42
34

14

22

42
34

21

22
14

13

11

12

22

21

22
12

14

22

21
11

13

21

41

42
34

33

33

41

21
11

22

21
11

12

12

11

21

22

11

21

41

33

33

34

42

41

14

13

21

22

13

21

41

33

33

34

42

41

Door closed

Door open

GP.-528H… 

1 NC c  

 

1 NO contact

Figure 5:  Minimum door radii

Actuator

Door radius min. 

[mm]

Actuator P-G…

1000

Actuator P-W…

1000

Hinged actuator P-OU…

90

Hinged actuator P-LR…

100

Hinged actuator P-LR/P-LRN

R > 10

0

Hinged actuator P-OU/P-OUN

12

26

20

35

28

+2

R > 90

Figure 4:  Dimension drawing GP…

2.
1.

1.

2.

3.

3.

4.

4.

6

8

5

7

4

3

2

1

4

5

6

7

8

11

9

3

2

1

10

PE

Ordinal numbers of switching elements

Terminal assignment with plug connec-

tor SR11

Connector illustration

Plug connector SR11

View of safety switch connection side

(not 

connected)

Necessary minimum permissible overtravel

Approach direction

Standard actuator

Overtravel actuator

Horizontal (h)

28 + 2

28 + 7

Vertical (v)

29.5 + 1.5

Order actuator separately

Insertion depth

40

30
31

3

4,1

5,1

V

M=0,8Nm

16

35

43

12

5

42

3,

5

32

31

22

16

M=0,8Nm

h

0,3 A

0,3 B

28

A

B

Fixed positioning for safety-relat-

ed applications (screw M5)

Optional LED indicator (only 

GP…528H/GP…538H)

Inser

tion 

depth

* Thread according to rating 

plate: 

- M20 x 1.5 

- NPT ½"

* Thr

ead (3x)

With plug connector SR11

  4

  35

  47

  130

A

B

C

D

0,3 A

h

v

  3

A

31

3,5

B

0,3

B

M=0,8Nm

3,5

8,5

16

With insertion funnel

Содержание 089725

Страница 1: ... die Stellung von beweglichen trennenden Schutzeinrichtungen Beim Einführen Herausziehen des Betätigers werden die Schaltkontakte betätigt Schaltzustände Die detaillierten Schaltzustände für Ihren Schalter finden Sie in Bild 3 Dort sind alle verfügbaren Schal telemente beschrieben Schutzeinrichtung geöffnet Die Sicherheitskontakte sind geöffnet Schutzeinrichtung geschlossen Die Sicherheitskontakte...

Страница 2: ...teile die mit einer Span nung von über 150 V arbeiten so getrennt werden dass ein ständiger Abstand von 50 8 mm eingehalten wird Es sei denn die beweglichen Leitungen sind mit geeigneten Isoliermaterialien versehen die eine gleiche oder höhere Spannungsfestigkeit gegenüber den anderen relevanten Anlagenteilen besitzen EU Konformitätserklärung Die Konformitätserklärung ist Bestandteil der Be triebs...

Страница 3: ...usbetätiger P LR 100 Radiusbetätiger P LR P LRN R 100 Radiusbetätiger P OU P OUN 12 26 20 35 28 2 R 90 Bild 4 Maßzeichnung GP 2 1 1 2 3 3 4 4 6 8 5 7 4 3 2 1 4 5 6 7 8 11 9 3 2 1 10 PE Ordnungsziffer der Schaltelemente Kontaktbelegung mit Steckverbinder SR11 Steckerbild Steckverbinder SR11 Ansicht Steckseite Sicherheitsschalter nicht angeschlossen Erforderlicher Mindestweg zul Nachlauf Anfahrricht...

Страница 4: ...n The safety switch monitors the position of movable safety guards The switching contacts are actuated on the insertion removal of the actuator Switching states The detailed switching states for your switch can be found in Figure 3 All available switching elements are described there Safety guard open The safety contacts are open Safety guard closed The safety contacts are closed Selection of the ...

Страница 5: ...ntained This does not apply if the moving cables are equipped with suitable insulation materials which possess an identical or higher dielectric strength compared to the other relevant parts of the system EU declaration of conformity The declaration of conformity is part of the operating instructions and it is included as a separate sheet with the unit The original EU declaration of conformity can...

Страница 6: ... Hinged actuator P OU 90 Hinged actuator P LR 100 Hinged actuator P LR P LRN R 100 Hinged actuator P OU P OUN 12 26 20 35 28 2 R 90 Figure 4 Dimension drawing GP 2 1 1 2 3 3 4 4 6 8 5 7 4 3 2 1 4 5 6 7 8 11 9 3 2 1 10 PE Ordinal numbers of switching elements Terminal assignment with plug connec tor SR11 Connector illustration Plug connector SR11 View of safety switch connection side not connected ...

Страница 7: ...troduction retrait de la languette a pour effet d actionner les contacts de commutation États de commutation Vous trouverez les états de commutation détaillés pour votre interrupteur à la Figure 3 Tous les élé ments de commutation disponibles y sont décrits Protecteur ouvert Les contacts de sécurité sont ouverts Protecteur fermé Les contacts de sécurité sont fermés Choix de l élément d actionnemen...

Страница 8: ...écessaire si les câbles mobiles sont munis de matériaux isolants adaptés présentant une résistance diélectrique égale ou supérieure aux autres composants importants de l installation Déclaration de conformité UE La déclaration de conformité fait partie intégrante du mode d emploi et est fournie avec l appareil sur une feuille séparée Vous trouverez aussi la déclaration UE de conformité originale s...

Страница 9: ...ticulée P LR 100 Languette articulée P LR P LRN R 100 Languette articulée P OU P OUN 12 26 20 35 28 2 R 90 Figure 4 Dimensions GP 2 1 1 2 3 3 4 4 6 8 5 7 4 3 2 1 4 5 6 7 8 11 9 3 2 1 10 PE Numéro ordinal des éléments de commutation Affectation des contacts avec connecteur SR11 Brochage connecteur Connecteur SR11 vue côté interrupteur de sécurité non raccordé Course mini nécessaire surcourse adm Di...

Страница 10: ...erruptor de seguridad supervisa la posición de los resguardos de seguridad móviles Al introducirse extraerse el actuador se accionan los contactos de conmutación Estados de conmutación Los estados de conmutación detallados de los interruptores se muestran en la Figura 3 También se describen todos los elementos de conmutación disponibles Resguardo de seguridad abierto Los contactos de seguridad est...

Страница 11: ...enos que los cables móviles cuenten con un aislante adecuado que tenga una rigidez dieléctrica igual o superior en comparación con las demás piezas relevantes de la instalación Declaración de conformidad UE La declaración de conformidad forma parte del manual de instrucciones y se entrega en una hoja aparte junto con el aparato La declaración de conformidad UE original también se puede consultar e...

Страница 12: ...dial P LR 100 Actuador radial P LR P LRN R 100 Actuador radial P OU P OUN 12 26 20 35 28 2 R 90 Figura 4 Plano de dimensiones GP 2 1 1 2 3 3 4 4 6 8 5 7 4 3 2 1 4 5 6 7 8 11 9 3 2 1 10 PE Cifras asignadas a los elementos de conexión Asignación de contactos con conector SR11 Imagen de contactos Conector SR11 Vista del lado de conexión del interruptor de seguridad no conectado Recorrido mín necesari...

Отзывы: