Figure 5: Min. door radii
Hinged actuator Z-L-C2194 / Z-R-C2194
Hinged actuator Z-L / Z-R
Hinged actuator Z-U / Z-O
Actuator type
Door radius min. [mm]
ACTUATOR-Z-G...
1000
HINGED ACTUATOR-Z-R
400
HINGED ACTUATOR-Z-L
400
HINGED ACTUATOR-Z-.-C2194
200
HINGED ACTUATOR-Z-U
165
HINGED ACTUATOR-Z-O
165
23
70
10
31
10˚
35
22
30
7
5,5
Ø
5,5
8
16
14
28
20
40
50
20°
92
Ø
5,5
8
16
14
28
20
40
50
20°
92
Z-L
Z-R
40
50
4
23
29
70
Ø 5,5
14
Z-L
Z-R
Z-U
Z-O