FLOOR/HOME FIXTURE
Technical Specification
PLEASE READ BEFORE INSTALLING
Keep away from fire.
Keep away from water.
Not for outdoor use.
To be installed by a
qualified electrician/
installer.
CAUTION
Backplate Guide
INSTALLING PARTY
All Power Tracks must be installed by a qualified
electrician.
USE OF EARTH LEAKAGE CIRCUIT BREAKER (ELCB)
It is a mandatory requirement that all installations of
electrical
power source must be connected to an ELCB to provide
protection against overload, short circuits and earth
leakages
faults. Failure to comply can be harzadous.
INSTALLATION LOCATION
All Power Tracks must be installed at location that
complies with safety rules and regulations of respective
country.
INSTALLATION SURFACE
All Power Tracks must be installed on flat surface.
RECOMMENDED INSTALLATION CLEARANCE
Refer to
FIG.1
on the right for more information on the
minimum clearance (from the floor or any furniture
fixtures) required for ‘twist-on’ adaptors and accessories.
Prepare leads as shown:
10mm
10mm
50mm
40mm
1) Do not use in damp environment.
2) If in doubt, please consult a qualified electrician.
Live (Brown or Red)
Earth (Green or Green/Yellow)
Neutral (Blue or Black)
Product Orientation
V-GROOVE AT BOTTOM
SH1
Power and Data Track (With SFC3)
Installation Guide
Product Overview
Wiring Instructions
Screw Cap
Pan Head Self Tapping Screw
SH1 End Cap
SH1 Internal Corner Cap
MF1 Mounting Frame
SH1 Corner Link
SH1 External Corner Cap
SH1 Housing
SFC3 Modular Track
DS4 Data Socket Housing
FIG. 1 Minimum Clearance for SH1 Installation
Minimum clearance of 25mm from the bottom required.
Housing Joint Pin
75mm
SFC Blank Cover
SH1 Retainer
25mm
Measurement Guide
ATTACHING ACCESSORIES*
5mm
Overall Wall Length
x
y
DESCRIPTION
For internal corner joint:
Width of gap = 37mm
Width of end cap = 5mm
MEASUREMENT GUIDE
Formula
SH1 Housing Length
(x - 37 - 5)mm
a
(y - 37)mm
b
(z - 5)mm
c
z
SH1 Housing
Length
a
b
c
End Cap
End Cap
* Compatible Accessories:
KH Kitchen Hook
KR Kitchen Rail
Live Terminal
Neutral Terminal
Live and Neutral Indicator
Earth Terminal
SFC3 Track
For SFC3 Modular Track
Rated Voltage
: 250V a.c. Single-phase
Rated Current
: 32Amp maximum
Frequency
: 50Hz / 60Hz
Rated Impulse Withstand Voltage : 4000V a.c.
Connection of Adaptor or
Tap-off Unit
: Intended to be connected
and disconnected when
when system is energized
and with a load connected
Terminal Connecting Capacity
(Live, Neutral and Earth)
: 1.25mm² to 6mm²
Ambient Operating Temperature
: -5°C to +55°C (not to
exceed an average of more
than 35°C in any 24 hours
period)
Maximum Installation Altitude
: 2000 metres
Degree of Protection
: IP4X
Resistance to Impact
: Heavy Impact
Degree of Pollution
: 2 (Non-conductive pollution
with temporary conductivity
caused by condensation)
Track and Housing Material
: Aluminium
Insulation Material
: Polycarbonate
Internal Corner
Cap
External
Corner Cap
a
b
c
x
y
z
5mm
5mm
37mm
DM
K-0
05-01
6-0
3 ENG
SFC3 Track Length
< 400mm
400 - 600mm
601 - 1100mm
1101 - 1500mm
1501 - 2500mm
2501 - 3300mm
3
4
6
9
12
15
3
2-2
3-3
3-3-3
3-3-3-3
3-3-3-3-3
-
100mm
160mm
160mm
160mm
160mm
Quantity (Pcs)
Arrangement
a
(mm)
SFC3 Track
Housing
a
a
*Where
a
is the length between the edge of the SFC3 Track to
the outermost edge of the backplate.
Attaching Multiple Backplates