![eTung ER-800 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/etung/er-800/er-800_user-manual_2434574048.webp)
ER-800 User Manual
48
After mServer is installed, double-click mServer’s icon on the desktop to run
mServer console, choose “System Settings”, in tab “Service Settings”, choose
TCP for link mode, and set listen port as 9000.
Figure Appendix 3-9: Configure mServer
2.
Configure APN parameters in the router
As step 1 in solution one shows, configure APN parameters in the router’s
configuration web page.
3.
Configure DMZ host in the router
First, connect data center server to the router with Ethernet cable.
Then, set static IP address in the data center server, and the IP address must
be in the same IP range as the IP address of the router’s Ethernet interface, for
example, 192.168.1.*. The figure below shows the server’s static IP address is
set to 192,168.1.100, and gateway and DNS are set to 192.168.1.1.