ETS-Lindgren 8000-003 Скачать руководство пользователя страница 1

Model 8000-003 

RF Power Amplifier 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание 8000-003

Страница 1: ...Model 8000 003 RF Power Amplifier User Manual ...

Страница 2: ...rein nor does it convey any license under its patent rights nor the rights of others All trademarks are the property of their respective owners Copyright 2014 by ETS Lindgren Inc All Rights Reserved No part of this document may be copied by any means without written permission from ETS Lindgren Inc Trademarks used in this document The ETS Lindgren logo is a registered trademark and Calibration Ser...

Страница 3: ...ons 11 4 0 Before You Begin 13 Unpacking 13 Safety Information 13 Warnings 14 5 0 Installation 15 Star Delta Configuration 15 Mains Input 15 Amplifier Protection 15 6 0 Operation 17 Equipment Use 17 Mains Switch 17 Standby Operate Switch Centre Unit 17 Fault Indicator Red LED 18 Interlock Indicator Orange LED 18 Local Lockout Indicator 18 RF Input Depending on model 18 RF Output Depending on model...

Страница 4: ...iv www ets lindgren com Warranty Exclusions 22 Buyer s Remedies 22 Appendix B EC Declaration of Conformity 25 ...

Страница 5: ...ted maximum input level as this can cause a risk of damaging the equipment Warning There is a significant risk of an electrical or burn hazard to avoid this always ensure the output is terminated prior to switching on the equipment Protective Earth Ground Safety Ground Indicates protective earth terminal You should provide uninterruptible safety earth ground from the main power source to the produ...

Страница 6: ...vi www ets lindgren com This page intentionally left blank ...

Страница 7: ...ss temperature sensing A front panel fault indicator is provided to indicate over temperature loss of air flow or fan failure and any potential imbalance between the 250W amplifier units The amplifier is designed for rugged operation into a variety of loads and is primarily intended for use as an RF power source for EMC susceptibility testing but is also applicable to other systems requiring a wid...

Страница 8: ...8 Introduction www ets lindgren com This page intentionally left blank ...

Страница 9: ...ge 13 WARNING There are no user serviceable parts within the 8000 003 amplifier system Maintenance of the amplifier system is limited to the external cables WARRANTY To prevent electrical shock DO NOT remove the covers Warranty will be void if the covers are opened ALWAYS UNPLUG THE UNIT BEFORE CLEANING Clean the exterior of the cabinet using a damp cloth Note The cables which form part of the amp...

Страница 10: ...st Order SRO 2 Briefly describe the problem in writing Give details regarding the observed symptom s or error codes and whether the problem is constant or intermittent in nature Please include the date s the service representative you spoke with and the nature of the conversation Include the serial number of the item being returned 3 Package the system or component carefully If possible use the or...

Страница 11: ...stantaneous 80MHz 1000MHz Rated Output Power 500W Minimum Output Power at 1dB Gain Compression 440W Minimum Gain 58dB Third Order Intercept Point 66dBm Gain Variation with Frequency 3dB Harmonics at 400W Output Power Better than 20dBc Output Impedance 50 Ohms Stability Unconditional Output VSWR Tolerance Infinity 1 Input VSWR 2 1 RF Connector Style Input Type N Female Output 7 16 Female Safety Int...

Страница 12: ...12 Specifications www ets lindgren com This page intentionally left blank ...

Страница 13: ...n contact ETS Lindgren Customer Service for further advice Safety Information This RF amplifier has been designed and tested in accordance with BS EN61010 1 and has been supplied in a safe condition This manual contains warning information which must be followed to ensure safe operation and to retain the apparatus in a safe condition This apparatus does not incorporate components liable to explode...

Страница 14: ...outlet provided with a protective earth contact The protective action must not be negated by the use of an extension cord without a protective conductor The opening of covers or removal of parts is likely to expose live parts This apparatus must only be serviced by qualified service personnel and must be disconnected from all voltage sources before it is opened for adjustment replacement maintenan...

Страница 15: ...9 3 phase plug Star Y configuration is supplied with a 5 pin plug Delta configuration is also supplied with a 5 pin plug although neutral is present it is unused If the plug requires rewiring the brown black and grey lines are live 1 2 and 3 respectively blue is neutral Star Y only and green yellow is earth Amplifier Protection The amplifier is protected by means of a miniature circuit breaker MCB...

Страница 16: ...16 Installation www ets lindgren com This page intentionally left blank ...

Страница 17: ...terminated into a suitable load prior to switching on the equipment Equipment Use The equipment must only be used for its intended purpose All parts of the equipment must remain connected to ensure that protective circuits operate Disconnecting parts of the equipment may impair operation and safety Mains Switch The amplifier is switched on or off by pressing the green red button on the front of th...

Страница 18: ... amplifier will return to Standby mode when the interlock is released Local Lockout Indicator This indicator is used when the USB GPIB Interface option is fitted Refer to the separate Remote Control Interface manual supplied RF Input Depending on model The RF input will accept a signal from an RF generator This input must be within the operating frequency range of the 8000 003 amplifier system An ...

Страница 19: ...Interlock must be O C If the Interlock is O C or the Interlock is S C the amplifier will be muted The amplifier is delivered without the interlock applied and will be ready to operate The interlock function is latching so when the interlock is removed the amplifier will be in standby mode Press the standby operate switch to return to normal operation Current drawn from the interlock BNC connectors...

Страница 20: ...20 Operation www ets lindgren com This page intentionally left blank ...

Страница 21: ... to correct a warranty failure shall be warranted to the extent of the unexpired term of the warranty applicable to the repaired or replaced product The warranty period shall commence on the date the product is delivered to Buyer however if Seller assembles the product or provides technical direction of such assembly the warranty period for such product shall commence on the date the assembly of t...

Страница 22: ...er s product with any product furnished by others 7 combining incompatible products of Seller 8 interference with the radio frequency fields due to conditions or causes outside the product as furnished by Seller 9 improper or extraordinary use of the product or failure to comply with any applicable instructions or recommendations of Seller including maintenance calibration and cleaning procedures ...

Страница 23: ...T INCIDENTAL OR CONSEQUENTIAL DAMAGES OF ANY KIND ARISING OUT OF OR AS A RESULT OF THE SALE DELIVERY NON DELIVERY SERVICING ASSEMBLING USE OR LOSS OF USE OF THE PRODUCTS OR ANY PART THEREOF OR FOR ANY CHARGES OR EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER S WRITTEN CONSENT DESPITE ANY NEGLIGENCE ON BEHALF OF THE SELLER IN NO EVENT SHALL SELLER S LIABILITIES UNDER ANY CLAIM MADE BY BUYER EXCEED ...

Страница 24: ...24 Warranty www ets lindgren com This page intentionally left blank ...

Страница 25: ...age Directive 2006 95 EC Model 8000 003 RF Power Amplifier Emission EN 61326 1 2013 Class A Electrical equipment for measurement control and laboratory use Immunity EN 61326 1 2013 Industrial level performance criteria A Electrical equipment for measurement control and laboratory use Safety EN 61010 1 2010 Safety requirements for electrical equipment for measurement control and laboratory use Tech...