Cold weather starting tips:
Most gas-powered generators are more difficult to start during cold temperatures. This generator has
been tested for cold weather starting, but it will still be more difficult to start the engine in
below-freezing temperatures.
Ease of starting improves if the generator has been stored under normal temperate conditions, such
as in a garage or a basement. Note: the generator should not be stored indoors unless all fuel has
been drained from it. Please see the section entitled 'Transportation/Storage' for more detailed
information.
In cold weather conditions, move the generator indoors for a period of 30 to 60-minutes, if possible, in
order to allow the components to warm up before attempting to start it.
CAUTION: Do not start the generator indoors. Move it back outdoors before attempting to start it.
When starting the generator at below-freezing temperatures, the following steps
are recommended:
•
Use 5W-30, 4-stroke formula (low temperature oil) engine oil instead of 10W-30 oil.
•
Verify that the engine oil level is appropriate (a low engine oil level will decrease the probability of
starting, and may damage the engine).
•
Check the fuel level (use only unleaded gasoline with an octane rating of 87 or higher).
•
Turn the fuel switch to the ON position.
•
Move the choke lever to the OFF (CLOSED) position (i.e.: minimum air and maximum fuel mix).
•
Verify that there is no appliance or other apparatus plugged into any receptacles.
•
Turn the engine switch to the ON position.
•
During the initial pull of the starter cord, pull lightly until resistance is felt. Continue to pull with
more effort, but slowly and evenly. This pull is intended to reduce mechanical resistance that is
built up due to the cold, and the period of non-use.
•
After the initial pull, pull the starter cord briskly 3 times, and then wait 15 seconds if the engine
does not start. The 15-second delay will allow excess fuel at the spark plug to evaporate. Failure
to delay for 15 seconds or pulling more than 3 times in a row may cause the spark plug to become
flooded. If the spark plug becomes saturated with fuel, the engine will not start.
•
Repeat the previous step until the engine starts
Note: the engine and the starter will warm up slightly with each pull. The engine will start more
easily once the engine and the starter are warm.
•
The engine may stop immediately after it starts. If this happens, repeat the starting procedure.
•
Once the engine has started and continues to run, allow it to run for 15 seconds, and then
gradually move the choke lever to the ON (OPEN) position (i.e.: proper mix of air and fuel).
•
Caution: Do not allow the starter cord to snap back against the engine. Guide it gently back into
position in order to prevent damage to the starter and the housing.
•
Caution: If the engine does not start after many pulls, inspect the spark plug. If the spark plug is
saturated with fuel and/or carbon deposits, clean it or replace it with a clean spark plug.