background image

1. CHANGING 

OIL  

Drain the oil while the engine is still warm (helps drain the oil faster). 

 

CAUTION: Make sure to turn the engine switch and the fuel cap lever to the OFF position 

before draining. 

 

● 

Loosen the cover screw and remove the left side maintenance cover. 

● 

Remove the oil filler cap. 

● 

Drain old engine oil into a container thoroughly. 

● 

Refill the crankcase with the recommended amount of oil; check the oil level before attempting 
to start the engine. 

● 

Reinstall the left side maintenance cover and tighten the cover screw securely. 

         
ENGINE OIL CAPACITY: 0.16L 
 

Picture 16 
 
 
 
 

 

MAINTENANCE COVER 

LEFT SIDE 

 

 
 

Picture 17 

 

NOTE: Please dispose of used motor oil in a manner that is compatible with the 

environment. Do not dispose in the trash, ground, or drains. 

 

OIL FILLER HOLE 

UPPER LEVEL

 

OIL FILLER CAP 

 
 

2.  AIR CLEANER SERVICE 

A dirty air cleaner will restrict air flowing into the carburetor. To prevent carburetor malfunction, 
service the air cleaner regularly. Service more frequently when operating the generator in 

19

 

Содержание IN800 i

Страница 1: ......

Страница 2: ...the air intake switch to off position 1 off 2 on Picture 1 Picture 2 2 After the engine is running turn the air intake switch to the On position 3 Move the adding pressure device up and down several times until you can feel the pressure when moving the device down Picture 3 4 wait 10 20 seconds then you can start it Remark Need to add inverter products working environment temperature MAX 40 1 Do n...

Страница 3: ... air cooled gasoline generators are widely used when electrical power is scarce Our generators provide a portable mobile solution in supplying power for field operations during project construction This manual will explain how to operate and service your generator set If you have any questions or suggestions about this manual please contact your local dealer or us directly Consumers should notice ...

Страница 4: ...MPONENT IDENTIFICATION 05 3 PRE OPERATION CHECK 07 4 STARTING THE ENGINE 10 5 GENERATOR USE 12 6 STOPPING THE ENGINE 15 7 MAINTENANCE TIPS AND INSTRUCTIONS 17 8 TRANSPORTING STORAGE 23 9 TROUBLESHOOTING FAQS 24 10 SPECIFICATIONS 25 11 WARRANTY 26 3 ...

Страница 5: ...ver run the generator indoors as the engine gives off poisonous carbon monoxide an odorless and colorless gas zInhaling carbon monoxide will cause nausea fainting or death zKeep the generator at least 3 feet away from flammable matter for adequate ventilation zBe sure to stop the engine before refueling zDo not overfill the fuel tank zIf fuel is spilled wipe it away carefully and wait until the fu...

Страница 6: ... outage zIf the generator is not installed properly it may explode burn or cause a fire in the building s electrical system when the power is restored zAlways conduct a pre operation inspection see page 7 before starting the engine zPlace the generator at least 1m 3ft away from buildings or other equipment during operation zOperate the generator on a level surface If the generator is tilted fuel s...

Страница 7: ...2 COMPONENT IDENTIFICATION FUEL CAP LEVER FUEL CAP CHOKE LEVER Picutre 4 CONTROL PANEL LEFT SIDE MAINTENANCE COVER FUEL VALVE STARTER GRIP ENGINE SWITCH SPARK PLUG MAINTENANCE COVER MUFFLER Picture 5 6 ...

Страница 8: ...CONTROL PANEL OUTPUT INDICATOR LIGHT OVERLOAD INDICATOR LIGHT OIL ALERT INDICATOR LIGHT Picture 6 AC RECEPTACLE GROUND 7 ...

Страница 9: ...el could result in serious damage to the engine NOTE The Oil Alert System will automatically stop the engine before the oil level falls below the safe limit In order to avoid the inconvenience of an unexpected shutdown it is recommended that the oil level be checked on a regular basis 2 CHECKING THE FUEL LEVEL Verify that the generator has sufficient fuel before each use When adding fuel after the...

Страница 10: ...ver Press the latch tab on the top of the air filter body remove the air filter cover and check the air filter Clean or replace the air filter if necessary CAUTION Do not run the engine without an air filter Rapid engine wear will result from contaminants such as dust and dirt being drawn into the engine through the carburetor Picture 8 OPEN COVER SCREW MAINTENANCE COVER LEFT SIDE Picture 9 AIR CL...

Страница 11: ...Picture 10 AIR CLEANER CASE AIR CLEANER ELEMENTS 10 ...

Страница 12: ...ove the choke lever to the CLOSED position Note Do not use the choke when the engine is warm or the air temperature is high CLOSED Move choke lever to the right to close 4 Pull the starter grip until resistance is felt then pull the starter grip briskly toward the arrow as shown below CAUTION Do not allow the starter grip to snap back Return it slowly by hand Picture 13 Starter Grip 5 Move the cho...

Страница 13: ...CLOSED shooting other areas Move choke lever to the left to open 12 ...

Страница 14: ...age and when utility power is restored the generator may explode burn or cause fires in the building s electrical system Picture 13 GROUND SYMBOL GROUND TERMINAL AC Applications Prior to operating your generator please Be certain that the generator and all appliances are in good working order Defective appliances or power cords can cause electrical shocks Make sure that the electrical rating of th...

Страница 15: ...he Engine page 10 for more information Before plugging in any appliances make sure that the total power rating of all the appliances does not exceed the power rating of the generator Plug in the appliance Motorized appliances usually use more power than their rated power for start up The overload indicator LED red will turn on if the generator is overloaded if load exceeds 750 watts If the generat...

Страница 16: ...nkcase Before the oil level in the crankcase falls below a safe limit the oil alert system will automatically shut down the engine The engine will not start if you try to start the engine with low oil the red oil alert indicator light will also light up If this occurs add engine oil Picture 14 OIL ALERT INDICATOR LIGHT RED 15 ...

Страница 17: ... to the STOP position IN NORMAL CONDITION 1 Switch off all connected appliances and disconnect them from the generator receptacles Picture 15 PLUG 2 Turn the engine fuel valve switch to the OFF position It should be located on the side of the generator under the recoil starter 16 ...

Страница 18: ... fuel cap lever counter clockwise to the OFF position CAUTION Be sure the fuel cap lever and the engine switch are on the OFF position when stopping transporting and or storing the generator FUEL CAP LEVER OFF 17 ...

Страница 19: ...ck the oil level Engine Oil Change the oil Air Cleaner Check the oil level clean and replace if necessary Fuel Filter Clean the fuel filter Replace if necessary Valve Clearance Check and adjust when necessary Fuel Line Check the fuel line for cracks or damage Replace if necessary Exhaust System Check for leakage Retighten or replace the gasket if necessary Check the muffler screen Carburetor Check...

Страница 20: ...e oil level before attempting to start the engine Reinstall the left side maintenance cover and tighten the cover screw securely ENGINE OIL CAPACITY 0 16L Picture 16 MAINTENANCE COVER LEFT SIDE Picture 17 NOTE Please dispose of used motor oil in a manner that is compatible with the environment Do not dispose in the trash ground or drains OIL FILLER HOLE UPPER LEVEL OIL FILLER CAP 2 AIR CLEANER SER...

Страница 21: ...extremely dusty areas Do not use gasoline or low flash point solvents for cleaning They are flammable and explosive under certain conditions COVER SCREW LEFT SIDE MAINTENANCE COVER 20 ...

Страница 22: ...ide maintenance cover Press the latch tab on the top of the air filter body and remove the air filter cover Wash the element using a non flammable or high flashpoint solvent and then dry it thoroughly Soak the element in clean engine oil and then squeeze out the excess oil Reinstall the air filter and the air filter cover Reinstall the left side maintenance cover and tighten the cover screw 21 ...

Страница 23: ...tion the spark must be properly gapped and free of deposits Remove the spark plug maintenance cover Picture 18 Remove the spark plug cap Clean any dirt around the spark plug base Use the wrench to remove the spark plug d COVER MAINTENANCE SPARK PLUG HANDLE BAR PLUG WRENCH SPARK PLUG CAP 22 ...

Страница 24: ... Avoid driving on rough roads for extended periods of time with the generator on board If it is necessary to transport the generator on a rough road drain the gasoline from the generator before transport Storage Verify that the fuel has been drained completely before transporting or storing the generator Long term storage longer than 30 days requires certain preventive procedures in order to guard...

Страница 25: ...hat there is no appliance or other apparatus plugged into any receptacles Turn the engine switch to the ON position During the initial pull of the starter cord pull lightly until resistance is felt Continue to pull with more effort but slowly and evenly This pull is intended to reduce mechanical resistance that is built up due to the cold and the period of non use After the initial pull pull the s...

Страница 26: ...magneto is defective The combustion chamber is properly supplied with fuel 4 The carburetor is not properly adjusted Call the Toll Free Helpline 1 888 908 6200 The fuel is not the proper grade Use the proper grade of fuel The generator is overloaded The generator is overheating Verify that there are not too many devices plugged in Check the fan The engine will not start The engine output is low Th...

Страница 27: ...ion System Full Transistor Oil Capacity 0 16 Liter 5 4 fl oz Fuel Tank Capacity 1 8 Liter 0 48 gallon Spark Plug A7RTC Noise Level 58 dB at 7 m Recommended replacement NGK CR5HSB Generator Rated Voltage 120 V Rated Frequency 60 Hz Rated Output 750 Watts AC Output Max Output 800 Watts Dimensions and Weight Length x Width x Height 448 x 248 x 375 mm 17 6 x 9 8 x 14 8 inch Dry weight 12 kg 26 46 poun...

Страница 28: ...mer use means personal residential household use by a retail consumer Commercial use means all other uses including the commercial income producing or rental purpose Once the engine has experienced commercial use it shall thereafter be considered as a commercial use engine for purpose of this warranty Engines use in competitive racing or commercial or rental tracks are not warranted A two year war...

Страница 29: ...vel daily or after every 8 hours of operation Refill when necessary and change at recommended intervals Engine damage may occur if oil level is not properly maintained Read Operating Maintenance Instructions 5 Repair or adjustment of associated parts or assemblies such as clutches transmissions remote controls etc which are not manufactured by Eastern Tools Equipment Inc 6 Damage or wear to parts ...

Страница 30: ...engine at no cost to you including diagnosis parts and labor OWNER S WARRANTY RESPONSIBILITIES As the small nonroad engine owner you are responsible for the performance of the required maintenance listed in your Owner s Manual Eastern Tools Equipment Inc recommends that you retain all receipts covering maintenance on your small nonroad engine but Eastern Tools Equipment Inc cannot deny warranty so...

Страница 31: ...h the Eastern Tools Equipment Inc Product Warranty may provide a longer warranty period Both the ECS Warranty and the Eastern Tools Equipment Inc product Warranty describe important right and obligations with respect to your new engine Eastern Tools Equipment Inc at its location in Ontario California can perform warranty service or any authorized service dealer near you At the time of requesting w...

Страница 32: ..._________ City_____________________________________________________ State_______ Zip Code___________________ Province or County_________________________________________________________________________________ Are you a Business Residence Product Usage Information How often will you use this product Everyday Periodically Emergency Use Only Other What type of application will you use this product in...

Отзывы: