ETQ
EASTERN TOOLS & EQUIPMENT INC
Tele: (888)908-6200
Web Site: easterntools.com
2
z
Avoid operating the engine with a dust cover.
z
Be sure to carry the generator only by its handle.
z
Put the machine on a flat surface. This will allow the machine to distribute the heat evenly.
4
)
ELECTRIC SHOCK PREVENTION
z
Never operate the engine in rain or snow.
z
Never touch the machine with wet hands or electrical shock will
occur.
z
Be sure to ground (earth) the generator.
The National Electric Code requires that the frame of generator
and the external electrically conductive parts of the generator be connected to an approved earth
ground. Local codes may differ and require other grounding specifications.
Using a No. 12 AWG (American Wire Gauge) stranded copper wire to the ground terminal and to
an earth-driven copper or brass grounding rod provides sufficient safety against shock. However,
local codes may differ. Contact a local electrician to find out specifications for grounding your
generator
5
)
CONNECTION NOTES
z
Avoid connecting the generator to commercial power outlet.
z
Avoid connecting the generator in parallel with any other generator.