GENERAL
11
Cab Control Panel
1. Spray Bar Switch
Turns all activated spray bar valves On or Off.
2. Hydraulic Oil Temperature Warning Light
Indicates that at the hydraulic oil temperature has
exceeded 180ºF. Stop immediately and determine the
cause of the high temperature. Failure to do so will re-
sult in damage to hydraulic components.
3. PTO Indicator Light
Indicates PTO engagement for units equipped with
a PTO driven hydrostatic pump.
4. Low Tank Level Indicator Light
Indicates low material level in the tank when lit.
5. Power Switch
Controls power to both the front and rear control pan-
els, either On or Off. Both the front and rear panel power
switches must be on to operate the distributor.
6. Bar Shift Switch
Moves the entire Spray Bar left or right. It is part of
the power lift, shift and wing fold option.
7. Bar Lift Switch
This switch raises and lowers the bar to the lower
bar stops and the upper position where it may be latched.
It is part of the power lift, shift and wing fold option.
8. Wing Fold Switches
Raise and lower the left and right wings. They are
also part of the power lift, shift and fold option. It is
possible to have three separate folding sections on each
wing. If you only have one folding section on a side
you will only have one switch per side, and so on.
9. Digital Display Screen
The digital display shows the application rate in gal-
lons/sq yd on the upper line of the display. The lower
line shows the speed in fpm on the left side and the
pump rate in gpm on the right side. Pushing the change
display button once will move you to the next screen
which shows the feet of bar selected, feet traveled and
the gallons sprayed since the last time the reset gallons
button or reset feet button was pushed. Pushing the
change display button again will move you to the next
screen which displays the sq. yd. shot since the last time
the reset buttons were pushed simultaneously. Pushing
the change display button again will move you to the
next screen which displays the material temperature
(optional). Pushing the change display button again will
move you to the next screen which displays the start
up factor. The start up factor sets how the spray bar
will act when it is first turned on. It is adjusted using
the Application Rate switch. The start up factor is nor-
mally set at 100% from the factory. If the start is thin or
weak, you can increase the start up factor to compen-
sate for this. A higher number will make the beginning
of the shot more aggressive or fatter. You may have to
change the start up factor by as much as 25 to 30% to
see the appropriate change. Conversely if the start of
the shot is too fat and heavy you would have to de-
crease the start up factor by as much as 25 to 30% to
get it where you want it. You can then make some finer
R
HYD OIL
HYD OIL
PT
PTO
LOW
LOW
TANK LEVEL
ANK LEVEL
FRONT
FRONT
REAR
REAR
SUCTION
SUCTION
3361133G
SHIFT
SHIFT
LIFT
LIFT
WING FOLD
WING FOLD
1
2
3
4
5
CHANGE
CHANGE
DISPLA
DISPLAY
RESET
RESET
GALLONS
GALLONS
LITRES
LITRES
RESET
RESET
FEET
FEET
METRES
METRES
ON
OFF
ON
OFF
APPLICA
APPLICATION
TION
RA
RATE
TE
POWER
POWER
CIRCULA
CIRCULATION
TION
RA
RATE
TE
SPRA
SPRAYBAR
YBAR
MEMOR
MEMORY
MAIN BAR
MAIN BAR
LEFT WING
LEFT WING
RIGHT WING
RIGHT WING
TEMP
TEMP
4
3
2
1
1
2
3
4
CIRC. IN TANK
LOAD
SUCK BACK
CIRC.
IN BAR
MARKER
12
11
10
9
8
7
6
5
5
6
7
8
9
10
11
12
MARKER
SUCKBACK
SUCKBACK
BAR
BAR
CENTERED
CENTERED
ON
ON
OFF
OFF
ON
ON
OFF
OFF
MIRROR
MIRROR
BAR LA
BAR LATCH
TCH
1
2
3
4
5
6
7
8
8
9
10
11
12
13
13
14
15
15
16
17
18
20
22
23
21
Component Location And Identification
CAB CONTROL PANEL
Содержание Black-Topper Shooter II
Страница 3: ...2 ...