background image

Major Parts

ON

OFF

ON

OFF

                                        Remote Transmitters                            Wireless Lock          
The user can select the following accessories (another sale) to unlock the lock as required:

Instruction of the keys on lock body

Note: 
1.Mechanical Switch: 

Used for installation and equipment trouble, please don’t press it often 

in the normal condition. When press the Mechanical Switch, the lock will be unlocked all the 
time until open the door one time by valid card, or valid PIN, or press the Exit button, or unlock 
button on Remote Transmitter.

2. ON/OFF Switch: 

When the button is off, the power of lock is off, all keys are useless except 

Mechanical Switch.
a.When the lock is unlocked, and you want to keep it unlocked, you can press the button OFF. 
The lock will work normally after press button ON.
b.When the lock is locked, and you want to keep it locked, you can press the Switch OFF, and 
then no one can access the door. The lock will work normally after press button ON.
When the button is on, the power of lock is on, the lock will be locked automatically in seconds 
and all keys can work normally.

Exit Button

Mechanical Switch

Pairing Key

LED Light

ON/OFF Switch

OFF: Power off
ON: Power on

Содержание ES-DLS-02

Страница 1: ...ES DLS 02 Wireless Security DockLock Base Set www etiger com ON OFF ON OFF ...

Страница 2: ......

Страница 3: ......

Страница 4: ...ickersprovideasimplewayforinstallation nodoor destroy nohole wireless nopowercab 433MhzRollingCodeofencryptionalgorithmand thesplitdesignguaranteehigher secure TheKeypadcanstore500PIN cardusers Becauseofultralowpowerconsumption the KeypadandRemoteTransmitterscanworkaslongasoneyear baseson30times day WirelessLockcanwork6months Itwillremindpeopletoreplacebatteriesintelligentlyif lowbattery 500PIN ca...

Страница 5: ...smitter WirelessLock OperatingHumidity Physical WirelessLock RemoteTransmitter Dimensions WirelessLock RemoteTransmitter UnitWeight WirelessLock RemoteTransmitter 500 4 8Digits 13 56MHzM1Card 4unitsofAAbatteries 1unitof2032Lithiumbattery Allitems 10uA 42mA 3mA 433MHz 50mMaximum 40 C 60 C 40 F 140 F 20 C 60 C 4 F 140 F 0 86 RH Zinc Alloy ABSShell ABSShell L184 W122 D26 mm L55 W32 D10 mm 800g 16g pc...

Страница 6: ...sstheExitbutton orunlock buttononRemoteTransmitter 2 ON OFF Switch Whenthebuttonisoff thepoweroflockisoff allkeysareuselessexcept MechanicalSwitch a Whenthelockisunlocked andyouwanttokeepitunlocked youcanpressthebuttonOFF ThelockwillworknormallyafterpressbuttonON b Whenthelockislocked andyouwanttokeepitlocked youcanpresstheSwitchOFF and thennoonecanaccessthedoor Thelockwillworknormallyafterpressbu...

Страница 7: ...tickpartofglassdoorbydrycloth Putthebatteriesintolock pressthelockbutton onRemoteTransmittertomakethespringboltprotruded Thisisforaligningtheotherpart Takeoutthe3Mstickersonthelock aligntheotherpart stickontheglassdoor pressthemfor someseconds Weusedhigh quality3Mstickers thestickinesswillbethebestafterstickingin 24hours Stick the lock on glass door Afterstickthelockonglassdoor peoplecanseethe3Mst...

Страница 8: ...3456isthefactorydefaultmastercode 0 NewCode RepeatNewCode code 6digits 1 UserID PIN RepeatPIN 1 ReadCard 1 UserID Readfingerprint RepeatReadfingerprint 2 UserID 2 ReadCard PIN ReadCard ReadCard PIN ReadFingerprint ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 Exit MasterCode Factorydefaultis123456 Set Master Code ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 UpdateMasterCod...

Страница 9: ... UserID PIN RepeatPIN Theuserscanbeaddedcontinuously Add Users Card s ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 AddCard UsingAutoID AllowstoassignCard tonextavailableUserIDnumber OR 2 AddCard SelectSpecificID AllowsMasterto defineaSpecificUserIDtoassociate thecard 3 Exit UserID 0 499 Cardtype 13 56MHzM1Card MasterCode 1 ReadCard Thecardscanbeaddedcontinuously 1 UserID ReadCard Add ...

Страница 10: ...erscanbedeletedcontinuously 2 ReadCard 2 MasterCode Set Access Mode ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 Ad2 PINAccess OR PIN CardAccess OR PINorCard 3 Exit MasterCode 30 31 32 factorydefault ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 Strike OutOFF OR 2 Strike OutON 3 Exit MasterCode 60 factorydefault 61 Set Buzzer ProgrammingStep KeystrokeCombination 1 EnterPro...

Страница 11: ...ssLockcanpair16parts Keypad RemoteTransmitter maximum 2 Whenpairing allpartsmustbepaired thenexitparingmode Ifneedaddingonemore part youstillneedtopairallpartsagain Step 1 Enter pairing mode OpenthebatterycoverofWirelessLock pressthesmallroundbuttonleftofbatterywitha slenderrod holditfor2secondsuntilhearingtwobeeps thatmeansinthepairingstatus Step 2 PairingWireless Keypad Pressthebutton 9 onthekey...

Страница 12: ... Trans mitter Exitfromthe program mode Anykeypresslow batteryiconturn on5 Sthenoff Lowbattery reminding Pairing ON Unlock thelock Lock Lock Lowbattery reminding LEDshining andbeeps Pressbutton RedLED Note Thelockwillopenautomaticallywhenthebatteryis tooloworrunout pleasechangethebatteryINTIME ONfor3 seconds Green LED Lowbattey ICON Whenthe LEDisdim pleasechange thebattery Buzzer Onebeep Onebeep On...

Страница 13: ...eTransmitters Manual ScrewDriver WallFixingPlus SelfTappingScrewsforkeypad Smallerones SelfTappingScrewsforlock Biggerones justincaseifneeded 3MStickers Oppositepaster Packing List Quantity 1pc 1pc 2pcs 1pc 1pc 4pcs 4pcs 10sets 4pcs 2pcs ...

Отзывы: