1.
Reinsert the PCB and use the fixing screw to fix the PCB
firmly.
2.
Connect the wires to the terminal block.
3.
Replace the front cover and make sure the tamper switch is
depressed when the front cover is clicked into place. Close
the housing firmly with the fixing screw.
The Walk Test
1.
The walk test can be performed as soon as the warm-up
delay is finished, in other words when the alarm LED stops
flashing. The walk test is necessary in order to verify
whether the device is in good working order and whether it
covers the desired area.
2.
The alarm will sound when both the upper and lower
channels are triggered simultaneously when the jumper is
in
the “NORMAL” position.
3.
If the jumper is in the “HARSH” position, the alarm will
sound upon simultaneous and double activation of both
channels in a space of 12 seconds.
4.
The detection range and the vertical angle of the device
can be adjusted by sliding the PCB up or down.
8.
Technical Specifications
current consumption ........................... 15 mA typical at 12 VDC
operating voltage ............................. 9-16 VDC, 12 VDC nominal
detection method ............... PIR detection with changing polarity,
.................................................
“Double –Twin Optics” system
warm-up delay .......... 2 min. typical, with flashing LED indication
alarm activation delay ..................................................... 2-3 s
alarm output ....... N.C. relay contact with a 10
resistor in series
................................................. contact rating: 28 VDC, 0.1 A
walk-test LEDs ............... upper/lower channels, alarm indicators
............................................. can be armed or disarmed at will
pulse counter ................................ normal response or 2 pulses
.............................................. within 12 s
in “HARSH”
-position
tamper switch ............ N.C. contact with a 10
resistor in series
................................................ contact rating: 12 VDC, 50 mA
Содержание HAA54
Страница 1: ...HAA54 USER MANUAL 3 HANDLEIDING 11 MODE D EMPLOI 19 MANUAL DEL USUARIO 27 BEDIENUNGSANLEITUNG 35 ...
Страница 2: ...HAA54 V 02 27 04 2020 2 Velleman nv ...
Страница 5: ...HAA54 V 02 27 04 2020 5 Velleman nv 5 Double Twin Optics System Detection of changing polarity ...
Страница 6: ...HAA54 V 02 27 04 2020 6 Velleman nv 6 PCB Layout ...
Страница 13: ...HAA54 V 02 27 04 2020 13 Velleman nv 5 Double Twin Optics systeem Detectie van wisselende polariteit ...
Страница 14: ...HAA54 V 02 27 04 2020 14 Velleman nv 6 Opmaak van de PCB ...
Страница 21: ...HAA54 V 02 27 04 2020 21 Velleman nv 5 Système Double Twin Optics Détection de polarité changeante ...
Страница 22: ...HAA54 V 02 27 04 2020 22 Velleman nv 6 Schéma du circuit imprimé ...
Страница 29: ...HAA54 V 02 27 04 2020 29 Velleman nv 5 Sistema Double Twin Optics Detección de polaridad cambiante ...
Страница 30: ...HAA54 V 02 27 04 2020 30 Velleman nv 6 Esquema del CI ...
Страница 37: ...HAA54 V 02 27 04 2020 37 Velleman nv 5 Double Twin Optics System Detektion der Polaritätsänderung ...
Страница 38: ...HAA54 V 02 27 04 2020 38 Velleman nv 6 Lay Out der Leiterplatte ...