background image

South Bend, Indiana USA 

 |

  networketi.com

PAVEMENT SENSOR INSTALLATION MANUAL  |  PART NO. 

23974

 REV 

A

2

INSTALLATION INSTRUCTIONS

1  Lay  out  the  sensor  housing  units  or  floor  boxes 

according to your plan for the size and shape of the 

pavement area and traffic overflow area.

2.  Using  a  screwdriver  or  similar  tool,  remove  the 

desired  knockout  seal(s)  from  the  floor  boxes. They 

won’t all be used. Knock out one of the two bottom 

seals in each floor box, as well, for greater stability as 

described in step 5 below.

3.  With  the  cap  off,  rotate  each  of  the  three  height 

adjustment  screws  to  the  left  to  raise  the  height 

adjustment  ring  between  an  1/8  and  a  1/4  of  an 

inch. Put caps back on housing units using the three 

retaining screws from the accessory kit.

4.  Once  the  adjustment  ring  has  been  raised,  apply  a 

layer of grease to the outside of the sensor housing 

body  underneath  the  height  adjustment  ring.  Also 

apply grease to the adjustment ring itself. Applying 

plenty of grease ensures the continued and proper 

operation  of  the  height  adjustment  ring  after  the 

pavement sets up and cures.

5.  Run PVC conduit between the floor box ports opened 

in step 2, as well as one for the control box wiring. 

Use  PVC  glue  to  secure  the  PVC  conduit  in  place 

inside each housing unit port. If not being used for 

wiring,  it  is  recommended  one  of  the  two  bottom 

ports be used as a drain with a short piece of conduit 

extending down past the concrete into sand or gravel. 

This promotes draining and provides greater stability 

for each floor box. Refer to Figure 1.

6.  As  the  paving  material  is  poured  and  sets  up, 

make sure the caps of all of the housing units are 

flush with the pavement. There must be no paving 

material on the caps of the housing units. Adjust the 

height flush with the pavement by using the height 

adjustment ring.

7.  To  install  a  sensor  into  a  housing  unit,  first  select 

the sensor housing unit to be fitted with the sensor. 

If  more  than  one  housing  unit  has  been  placed  as 

part of the installation, itis best to select the one it is 

believed will be closest to thecenter of the traffic or 

snow build-up pattern(s).

8. The next step will be to remove the housing cap and 

install  the  actual  sensor.  Refer  to  the  documentation 

accompanying the sensor for further instructions.

QUESTIONS AND COMMENTS

For technical help, questions, or comments concerning 

this  or  any  Environmental  Technology,  Inc.  product, 

contact the Customer Service Department between 8:00 

a.m. and 5:00 p.m. EST.

E-mail:

 [email protected]

LIMITED WARRANTY

ETI’s  two  year  limited  warranty  covering  defects  in 

workmanship and materials applies. Contact Customer 

Service for complete warranty information.

DISCLAIMER

Environmental Technology, Inc. makes no representations 

or warranties, either expressed or implied, with respect 

to the contents of this publication or the products that 

it  describes,  and  specifically  disclaims  any  implied 

warranties of merchantability or fitness for any particular 

purpose.  Environmental  Technology,  Inc.  reserves  the 

right  to  revise  this  publication,  and  to  make  changes 

and  improvements  to  the  products  described  in  this 

publication,  without  the  obligation  of  Environmental 

Technology, Inc. to notify any person or organization of 

such revisions, changes or improvements.

Copyright © 2019 ETI,

®