PRE-TEST INSTALLATION AND SET-UP (PI2500)
1.
The following components of the test set should be available and in good
condition:
a)
PI-2500 Main Unit
b)
Series bars (three pieces)
c)
Stab adapter plate assemblies (one set of four)
d)
Allen wrench (hex) to match socket head bolts
e)
Pneumatic or electric power ratchet
f)
Stab set or cables to match breaker to be tested
g)
Input power plugs and cables
h)
Input ground lead
i)
Auxiliary ground lead
j)
Contact lead set (If applicable)
k)
Remote initiate cable (optional)
2.
For 1000-amp output mode
a)
Attach series bars from output terminals 2 to 3, 4 to 5, and 6 to 7.
b)
Make sure they fit snugly between the output bus bars, and tighten the
bolts
c)
Attach cables as needed between output terminals 1 and 8.
d)
Make sure selector switch is set to 1000
3.
For 2000-amp output mode
a)
Attach series bars from output terminals 2 to 3, and 6 to 7.
b)
Make sure they fit snugly between the output bus bars, and tighten the
bolts
c)
Place the stab plate adaptor assembly stamped #1 on output bus #1,
making sure it aligns into the slot on the stab adaptor support block
d)
Tighten bolts securely.
e)
Repeat for stab plate adaptor assemblies stamped #4, #5, and #8