(Timer:
Press
the
button
in
short
time
lighting
time
will
switch:
0h,
2h,4h,6h,8h,
total
five
kind
of
light
time.
When
lighting
time
is
over,
the
light
goes
off,
and
the
light
on/off
cycle
is
24
hours.)
(Pair the grow light to remote controller: When the fixture is power on within 60s, switch to “remote
control” mode ,
press Paring button, the grow light will flash to indicate the fixture is connected. Grow light is controlled by pressing
the -/+ and on/off buttons on the remote controller. The light changes to indicate the grow light is controlled
successfully.)
(Delete connection: Select the grow light which is needed to be deleted by pressing Previous/Next
Button, within 5 seconds, press Delete button, the light flash three times represents disconnection is successful. Once
the selected grow light is deleted, this grow light will not be controlled any more.)
( Group Set Up: Select the grow light which is needed to be deleted by pressing Previous/Next Button, within 5
seconds, press any one of the buttons Group1, Group2,Group3, Group4, then the selected grow light will be group into
the related group.)
(Group Controll: Press any one of the buttons Group1, Group2,Group3, Group4 or ALL button, then press +/-
、
ON/OFF button, the group of grow lights can be controllerd. The light changes to indicate the grow light is controlled
successfully.)
(Notice: Above operation is based on “remote control” mode. The grow light can be controller when it is in
“remote control” mode. When timer points “OFF” mode, the timer on the remote controller can be set up.)
6. Maintenance instruction
6.1 Do Not use volatile solvent such as alcohol to clean the troffer.
6.2 Use soft cotton cloth with suds to clean the troffer .
6.3 Non-profecssional Do not attempt to take apart and repair the troffer .
6.4 Please use the constant-current driver exclusively adaptive to the troffer, do not
change the driver without permission .
7. Environment requirement
Operating temperature :-10~40℃;Storage temperature :-20~50℃。