background image

  

              1 / 9                                    

ETI d.d., Obrezija 5, SI-1411 Izlake 

http://www.etigroup.eu/products-services 

3PH - ENERGY METER 

 

TECHNICAL MANUAL OF INSTALLATION 

ENA3D                                  ENA3 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

INDEX

1 - BUTTONS  AND INDICATION LEDs: ................................................................................ 2 

2 - ELECTRICAL DIAGRAM FOR INSTALLATION: ............................................................... 2 

3 - SET-UP MENU: ................................................................................................................... 3 

4 - ENTER THE ALARMS MENU: ........................................................................................... 5 

5 - MEASUREMENTS FUNCTIONS: ....................................................................................... 6 

6 - TECHNICAL DATA: ............................................................................................................ 7 

7 - TERMINAL CONNECTIONS: ............................................................................................. 8 

8

 

-

 

DIMENSIONS: ..................................................................................................................... 9 

 

 
 

REGISTERS MODBUS-RTU TABLE ON REQUEST

 

 

 
 
 
 

 

 

!!! IMPORTANT !!! READ THE INSTALLATION MANUAL BEFORE USE.

 

 
THE SAFETY OF THE PRODUCT IS STRICTLY RELATED TO ITS USE THAT HAS TO BE 
DONE AS SPECIFIED BY THE MANIFACTURER. 

 
 
 

Содержание 004656578

Страница 1: ...Ds 2 2 ELECTRICAL DIAGRAM FOR INSTALLATION 2 3 SET UP MENU 3 4 ENTER THE ALARMS MENU 5 5 MEASUREMENTS FUNCTIONS 6 6 TECHNICAL DATA 7 7 TERMINAL CONNECTIONS 8 8 DIMENSIONS 9 REGISTERS MODBUS RTU TABLE...

Страница 2: ...RMS A Current Hz Frequency Cos Cos W True Power VAr Volt Amp Reactive VA Volt Amp Apparent V THD Total Harmonic Distortion Voltage A THD Total Harmonic Distortion Current Wh Watt hours VArh Volt Amp...

Страница 3: ...The installer has to provide an external disconnection device this breaker has to be easily reachable and identified as disconnection device Without transformer 1 For higher supply voltage than the su...

Страница 4: ...er Reading Interval 60s 360s 90s 2 Average time filter Value 1 20 4 1 Parameter adjusts the time window width for the integration of current and power maximum demand 2 Parameter allows to modify the s...

Страница 5: ...bus 19200 Bds NONE 1 Bit Stop 12 Modbus 9600 Bds NONE 1 Bit Stop 13 Modbus 4800 Bds NONE 1 Bit Stop 14 Modbus 2400 Bds NONE 1 Bit Stop 15 Modbus 1200 Bds NONE 1 Bit Stop 16 Proprietary 9600 Bds NONE 1...

Страница 6: ...disable 1 2 3 1 0 ALL 0 1 L1 2 L2 3 L3 Over Temperature 0 disable 30 60 60 1 240 10 Min Sec Sec 0 disable 1 2 3 1 THD I 0 disable 5 200 120 1 240 10 Min Sec Sec 0 disable 1 2 3 1 Low Cos 0 disable 0...

Страница 7: ...s Press both buttons for 15s to reset all VArh values i Only if set in Three Phase mode while select V measure the display shows the value for each Phase press it shows the phase voltages Press for mo...

Страница 8: ...ry Rated Voltage VDE0110 C 250 B 400 Maximum Switching Voltage 250V Electrical Contact Life 20 x 100 6 ops Mechanical Contact Life 100 x 10 3 ops Enclosure and Connections Cable Type for connection On...

Страница 9: ...IMENSIONS 144x144 MODEL FRONT VIEW SIDE VIEW PANEL HOLE 9 MODULE MODEL FRONT VIEW SIDE VIEW CLEANING OF THE UNIT If necessary clean the device with a soft cloth dampened with water This operation must...