KL8-3A User Manual
8
1 2 3 4 5 6 7 8
A
ON
1 2 3 4
B
ON
Fig 13
:
DIP Switch bank A and B
Ⅵ
.The Master Board Specifications and DIP switch jumper settings (Fig. 13)
A1
:
OFF
:
No preheating function.
ON
:
With preheating function.
A2
:
OFF
:
No circulation cleaning function.
ON
:
With circulation cleaning function.
A3
:
OFF: Ethink 4 wire 12v DC LED lights.
ON
:
12v AC 2 wire incandescent or LED lights.
A4
:
OFF
:
Display Celsius temperature.
ON
:
Temperature display can be selected by control panel. C or F.
A5
:
OFF
:
Can be equipped with up to two jet pumps. H220 or H380 heater.
ON
:
Can be equipped with three jet pumps. H380 heater only.
A6
:
OFF
:
When the temperature is abnormal or the sensor doesn’t detect the water, the
water pump and heater will stop working.
ON
:
Not used – leave off.
A7
:
OFF
:
With water flow sensor, if it detects no water flow, the heater will not work.
ON
:
Not used – leave off.
A8
:
OFF
:
With Ethink control panel.
ON
:
Not used – leave off.
B1
:
OFF
:
Normal mode.
ON
:
Not used – leave off.
B2
:
OFF
:
With radio function.
ON
:
Not used – leave off.
B3
:
OFF
:
The maximum working time for jet pump and blower is 25 minutes.
ON
:
The maximum working time for jet pump is 60 minutes and the blower
working time is 20 minutes.
Ⅶ
. Warning and Error codes
1.
When the system is showing any error code, please don’t use spa and go into water.
1.1 “E1”: The temperature sensor is short or open.
1.2 “FF”: The system detected that the temperature inside heater reach or over 48
℃