1.4 The wire connection for each load
Heater Line1
Heater Line2
Neutral1
Neutral2
Protective Earth
Heater Line
Empty
Neutral
Protective Earth
Fig. 15: Wire connection Fig. 16: Wire connection for
for H380 heater H220 heater
PUMP1 High Speed
Neutral
Protective Earth
PUMP1 Low Speed
Line
Neutral
Protective Earth
Empty
Fig. 17: Wire connection for 2-speed pump Fig. 18: Wire connection for others
Wire colours that may be used for cords fitted to outputs:
2 speed pumps:
Type 1
Type 2
Type 3 (LX, Davey)
Low speed -
Black
Black
Brown
High speed -
Brown
Red
Black
Neutral -
Blue
White
Blue
Earth -
Green/Yellow
Green
Neutral
It
’
s important that a 2 speed pump low/high speeds are checked for the correct configuration
–
heating/filtration should automatically run on low speed.
If it runs on high speed, swap the low and high speed wires at the pump terminal box.
1 speed pumps, blower, ozone etc:
Type 1
Type 2
Active -
Brown
Black
Neutral -
Blue
White
Earth -
Green/Yellow
Green