SFFR-6
User Manual
Configuration
Doc ID: ES1002-UM02-v204a
Copyright © 2014 Etherstack London Limited
Page 22 of 39
3.3 Managing Operational Profiles
GoBox profiles are managed under the
Profiles
heading in the navigation pane.
3.3.1 Adding a P25 Conventional Repeating Profile
To create a new P25 Conventional Profile, click the
P25 Conventional
menu item in the navigation pane and click on
+ Add
Profile
button on the content pane.
The following fields will be required to be completed.
Field
Description
Profile Name
Create a unique profile name that will appear in the Status Window of the GoBox control interface. This
name is what your operational profile will be called.
The Profile Name is limited to 8 characters and may only include letters, numbers or a hyphen '-'.
Duplexor Group Tag
If Duplexor Group Tags have been created, you can select a Duplexor Group to associate this profile with.
Selecting a specific Duplexor tag means this profile will only be available on the GoBox control interface if
the corresponding Duplexor is installed.
If Duplexor Group Tags have not been created, you can select
All
and then edit the profile once Duplexor
Group tags have been created. Selecting
All
means this profile option will always be available to select on
the GoBox control interface regardless of what Duplexor is installed.
Once an operational profile is associated with a Duplexor Group Tag, it may also be chosen as the default
start-up profile for a Duplexor.
Rx Frequency
This should be set to the desired centre receive frequency. The installed duplexer must be calibrated to this
frequency to ensure optimal RF performance.
Tx Frequency
This should be set to the desired centre transmit frequency. The installed duplexer must be calibrated to
this frequency to ensure optimal RF performance.
Tx Power
The transmit power in Watts to use for this operational profile.
Site ID
The Site ID indicates the identity of the P25 site and is inserted into over-the-air traffic. The Site Id must be
unique within an RFSS when the GoBox is used in Network mode.
The Site ID is limited to values between 0 and 255 (decimal).
If the user enters an invalid value in any form field, the GoBox will reject the profile, and the reason will be
displayed on the form in red.
!
Hovering over any form field name that has a dotted underline will display a popup tip to assist completing the
form.
!
Содержание SFFR-6
Страница 6: ...SFFR 6 User Manual 1 Introduction...
Страница 11: ...SFFR 6 User Manual 2 Getting Started...
Страница 18: ...SFFR 6 User Manual 3 Configuration...
Страница 29: ...SFFR 6 User Manual 4 Using the GoBox...
Страница 35: ...SFFR 6 User Manual 5 Troubleshooting...
Страница 37: ...SFFR 6 User Manual 6 Glossary...