background image

If you experience problems: 

 
If your light is defective or develops a fault, please return it to the place where you bought it. You can call our Helpline 
for advice. The Helpline will gladly give advice on any aspect of any Eterna Lighting product but may not be able to 
give specific instructions regarding individual installations.  

If in doubt, consult a qualified electrician.

 

 

Help line: 

 
Tel: 01933 673 144     

Fax: 01933 678 083 

Email[email protected] 

For answers to frequently asked questions ( FAQs ) and other information visit our web-site 

www.eterna-lighting.co.uk 

Lamp replacement: 

 

Switch off the electricity at the mains. 

Remove the diffuser. 

Twist and withdraw the tube. 

Insert new tube. 

Restore the power and perform operation check. 

Replace diffuser. 

 

Replacement lamp type: 

 
Wattage:  

8 W 

Type: 

 

T5 fluorescent tube 

 

Replacement battery type: 

 
2.4V Ni-Cad 
7030-0621 
 

Cleaning: 

 

Clean this light fitting only with a soft dry cloth—Do 
not use any chemical or abrasive cleaners. 

 

 

Battery replacement: 

 

If after routine operation check, the lamp does not 
remain lit for the three hour period, a new battery pack 
may be required. 
1)  Switch off the electricity at the mains. 
2)  Allow batteries to fully discharge then reconnect to 

supply and allow to charge for 24 hours. 

3)  Test again for 3 hours, if light does not remain lit 

change the battery pack as follows: 

4)  Remove the diffuser. 
5)  Remove the two screws indicated on the gear tray 

and open the fitting. 

6)  Unplug the battery lead from the circuit board. 
7)  Remove the two screws in the top of the gear tray 

beneath the lamp that secure the battery pack in 
place and lift the battery pack out of the fitting. 

8)  Write current date on the new battery pack. 
9)  Fit new battery pack securing in place using the 

screws removed from the old pack. 

10)  Plug battery pack into circuit board. 
11)  Close and secure gear tray 
12)  Replace diffuser. 
13)  Restore power and allow to charge for 24 hours. 
14)  Perform full operation check and update test record. 
 
 
 

Eventually, you may want to replace this light fitting: 

 
When  your  light  fitting  and  or  battery  pack  come  to  the  end  of  their  life  or  you  choose  to  update  or 
upgrade the fitting by replacing it, please do not dispose of it  with your normal household waste, please 
recycle where  facilities  exist. When  you  need  to  dispose  of  this  fitting,  check with  your  retailer  or  local 
authority for suitable options. New regulations will encourage the recycling of Waste from Electrical and 
Electronic Equipment ( European “WEEE Directive” effective August 2005 ). 

PLEASE READ THESE INSTRUCTIONS BEFORE INSTALLING 

YOUR NEW FITTING 

- - 

PLEASE RETAIN FOR FUTURE REFERENCE

 

Non-maintained emergency 

bulkhead light 8W

 

 

Model(s) 

YD630NM

 

Specification: 

 

Power 

8W 

Continuous illumination 

>3 hours @ 45Lm 

Battery 

2.4V  4.5Ah 

Recharge time 

~20 hours 

Over-discharge protection 

Yes 

 

 

 

BLF 

EBLF 

 

 

 

30.2% 

17.7% 

 

 

 

 

 

Отзывы: