Installation

Max Lux Detection Distance - 12m / 120º Angle

Mounting Height

1.5m - 2m

Floor Level

READ THIS FIRST

Check the pack and make sure you have all of 

the parts listed on the front of this booklet. If 

not, contact the outlet where you bought this 

product.

This switch must be installed by a 

competent person in accordance with the 

Building Regulations 

making reference to the 

current edition of the IEE Wiring Regulations 

(BS7671). The Building Regulations may be 

obtained from OPSI or viewed and downloaded 

from www.communities.gov.uk following the 

link for Building Regulations.

As the buyer, installer and/or user of this 

product it is your own responsibility to ensure 

that it is fit for the purpose for which you have 

intended it. Eterna Lighting cannot accept any 

liability for loss, damage or premature failure 

resulting from inappropriate use.

If in any doubt, consult a qualified electrician.

This product is designed and constructed 

according to the principles of the appropriate 

British Standard and is intended for normal 

service.

This PIR wall switch can be installed as a direct 

replacement for a normal one way wall switch. 

The switch body will fit into a standard wall box 

using the screws supplied.

Switch off the mains before commencing 

installation and remove the appropriate circuit 

fuse.

Do not overload the switch; check that the 

total wattage of all connected fittings does not 

exceed the maximum marked on the switch 

and listed below in these instructions.

Disconnect the Switch from the electrical supply 

before flash or high voltage testing.

Do not connect to a circuit which also has 

inductive loads connected as spikes generated 

switching inductive loads may cause erratic 

operation.

Suitable for indoor use only.

This product is suitable for use in living areas 

(not for areas constantly subject to moisture)

Before making fixing hole(s), check that there 

are no obstructions hidden beneath the 

mounting surface such as pipes or cables.

Do not attach to surfaces which are damp or 

freshly painted.

If the location of your new switch requires the 

provision of a new electrical supply, the supply 

must conform with the requirements of the 

Building Regulations making reference to the 

current edition of the IEE Wiring Regulations 

(BS7671).

When making connections, ensure that the 

terminals are tightened securely and that 

no strands of wire protrude. Check that 

the terminals are tightened onto the bared 

conductors and not onto any insulation. 

This switch is double insulated; do not connect 

any part to earth.

There is no provision for connection of ring 

wires, ring wires should be joined using a 

separate terminal block and insulated well.

Do not connect to Neutral, no neutral 

connection is required for the correct operation 

of this switch. Any neutral wires present should 

be terminated separately and insulated well.

You are advised at every stage of your 

installation to double-check any electrical 

connections you have made. After you have 

completed your installation there are electrical 

tests that should be carried out: these tests are 

specified in the Wiring Regulations (BS7671) 

referred to in the Building Regulations. If in 

doubt, consult a qualified electrician. 

 

CLEANING

Clean this light switch only with a soft dry cloth.

Do not use any chemical or abrasive cleaners.

INSTALLATION

1)  Connect the live supply wire to the LIVE IN 

terminal.

2)  Connect the live wire from your light fitting(s) 

to the LIVE OUT terminal

3)  Turn the TIME control to minimum (-)

4)  Turn the LUX control towards the sun (

)  

symbol

5) Turn the battery switch to the ON position

6)  Fix the switch into your back or pattress box 

using the 2 screws supplied

7) Restore the power.

8)  The switch will begin switching as movement 

of warm bodies is detected. The PIR will switch 

off approximately 5 seconds after the last 

movement is detected.

9)  If the switch is switching your light fittings 

correctly you can then adjust the time setting to 

suit the installation function (5 sec to 15 min). 

We recommend that a minimum of 2 minutes 

be set for fluorescent lights or fittings with CFLs 

installed.

10)  When the ambient light is at the level at 

which you want to PIR to switch on and 

off, slowly turn the LUX control until the PIR 

switches off. Note that the determination of 

ambient light by the human eye is subjective 

and approximate, this step may need to be 

repeated two or three times to find the most 

satisfactory setting.

 

ADDITIONAL SWITCHES

Additional switches may be connected in parallel. 

 

OPERATION

Once set up, the switch will operate when 

movement is detected, the timer set to turn off the 

lights will recommence with every detection. The 

lights will turn off at the pre-set time after the last 

movement has been detected.

The rocker switch on the right hand side of the 

wall switch over-rides the automatic function to 

maintain the switch in power-on mode until the 

rocker is switched back to auto.

“Auto position”

 the unit works on PIR detection 

at the pre-set LUX level and duration TIME.

“ON position”

 means light will stay on 

continuously whether or not the PIR has been 

triggered. When the switch has been turned back 

to Auto it will switch off after the pre-set time has 

elapsed.

TIME

+

-

LUX

É

Lamp

Time & Lux Settings

Out  L

On 

Off

Battery On / Off 

Switch - Turn on  

when mains applied

Auto

On

Live

Neutral

Lamp