background image

READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product must be installed by a competent 

person in accordance with the current building and 

IEE wiring regulations.

 As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.

This product is designed and constructed according 

to the principles of the appropriate British Standard 

and is intended for normal service. Using this fitting 

in any other environments may result in a shortened 

working life, for example where there is prolonged 

periods of use or higher than normal ambient 

temperatures. 

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse or lock off 

MCB.

Disconnect the Driver / dimmer from the electrical 

supply before flash or high voltage testing.

Do not connect to a circuit which also has inductive 

loads connected; switching of inductive loads will 

generate spikes which may damage electronic 

components within your driver / dimmer.

This unit is suitable for outdoor use.

This product is designed for permanent connection 

to fixed wiring: this must be a suitable circuit 

(protected with the appropriate MCB or fuse).   

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

Make sure that the fixings are strong enough to 

support the considerable weight of the fitting and 

hold it rigidly.

The chosen location of your new fitting should 

allow for the product to be securely mounted (e.g. 

to a ceiling joist) and safely connected to the mains 

supply (lighting circuit).

When making connections ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened 

onto the bared conductors and not onto any 

insulation. 

This product must be connected to earth 

termination.

This product is not intended to be used by children 

and persons with sensory, physical and/or mental 

impairments that would prevent them from using it 

safely.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out, 

these tests are specified in the current IEE wiring and 

building regulations.

 

OPERATION CHECKS:

Periodic testing should be carried out to ensure 

emergency lighting is operating correctly. 

Interruption of the supply, causing the fitting to be 

energised from the battery, should be carried out by 

the operation of a local keyswitch or other isolation 

device. During this period all fittings should be 

examined visually to ensure that they are functioning 

correctly. At the end of the test period the supply 

shall be restored and all indicator lamps or devices 

checked to ensure that the normal supply has been 

restored. 

DAILY:

 

Visual inspection of the battery charge LED.

EACH MONTH:

 

Isolate the power supply for a period sufficient to 

ensure that each lamp is illuminated. Endorse the 

test record form supplied.

ONCE EACH YEAR:

 

Isolate the power supply and check that the light is 

still illuminated after 3 hours. Endorse the test record 

form.

Because of the possibility of a failure of the normal 

lighting supply occurring shortly after a period of 

testing of the emergency lighting system or during 

the subsequent recharge period, all full duration 

tests shall wherever possible be undertaken 

preceding time of low risk to allow for battery 

recharge.

 

NOTE: please keep this instruction booklet and 

the test record in a safe place. A fire officer or 

other authorised person may want to see your 

record of inspection and testing.

 

INSTALLATION:

01)  Choose the location of your new fitting giving 

consideration to all of the conditions listed above 

and the position of the entry points for the mains 

supply cable.

02)  Put finger in the hole on top of the clip and pull 

outwards to release the diffuser clips to open up 

the fitting.

03)  Press together the tops of the clips protruding 

through the middle of the gear tray and lift the 

tray out of the fitting.

04)  If fixing direct to a mounting surface, clear 

through the mounting holes on the back of the 

fitting, visible from the outside, using a 5mm drill.

05)  Using the back of the fitting as a template, mark 

the location of the fixing holes on your mounting 

surface.

06)  If fixing directly to a solid surface, drill holes and 

insert the plastic plugs supplied.

07)  Secure your fitting in position using the screws 

and washers supplied. Put the washer onto the 

screw before fixing. If the fixings supplied are 

not appropriate to your installation, please select 

suitable alternatives. Take care not to over tighten 

fixing screws to prevent damaging the case.

08)  Hanging clips are supplied to allow you to 

suspend the fitting from chains (not supplied).

09)  Ensure that the chain is strong enough to support 

the weight of the fitting and that the tops of the 

chains are fixed securely to the mounting surface.

10)  Pierce the centre of the grommet at the end of 

the fitting adjacent to the supply wiring. Take 

care not to make the hole too large as the tight 

fit of the gland to the cable is essential for it to 

retain its IP rating. Alternatively, fit a gland/nut 

assembly.

11) Thread the supply cable through the gland.

12)  Make connections to the terminal block on the 

back of the white metal gear tray according to the 

following colour code:  

 

Neutral - Blue or Black 

Earth - Green and Yellow 

PL (Permanent Live) - Brown/Red  

SL - (Switch Live) - Brown/Red

13)  Adjust the microwave sensor settings as required.

14)  Locate the gear tray over the metal clips 

protruding from the case and press the gear tray 

into position. Ensure that all clips have latched 

securely.

15)  Hold the diffuser in position on the fitting so that 

it is seated on the soft foam gasket all the way 

around.

16)  Position the bottom of each clip hook in the lip of 

the diffuser and press the thumb catches up and 

over to lock firmly in position.

17) Restore the power supply and switch on.

DANGER!

NOTE:

 this unit has a  permanent live mains supply, 

please ensure you isolate before removing cover.

There may also be a seperate switched supply that 

controls the emergency light fitting - this also needs 

to be isolated.

Yellow/Green

EARTH

PL

N

Blue/Black

Brown/Red

Brown/Red

SL

NEUTRAL

PERMANENT LIVE

SWITCH LIVE