READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product must be installed by a competent 

person in accordance with the current building and 

IEE wiring regulations.

As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.  

This light fitting must be installed in accordance with 

the Building Regulations making reference to the 

Wiring Regulations BS7671.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse.

Suitable for indoor or outdoor use.

This product is suitable for installation with normal 

flamibility e.g wood, plasterboard and masonry.

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

The chosen location of your new fitting should 

allow for the product to be securely mounted (e.g. 

to a ceiling joist) and safely connected to the mains 

supply (lighting circuit).

Ensure that the fitting will be accessible after 

installation for maintenance.

If the location of your new fitting requires the 

provision of a new electrical supply, the supply 

must conform with the requirements of the Building 

Regulations making reference to the Wiring 

Regulations (see above).

Make connections to the electrical supply in 

accordance with the following code: 

 

Live - Brown or Red 

Neutral - Blue or Black

This product is double insulated. Do not connect 

any part to Earth.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out: 

these tests are specified in the Wiring Regulations 

(BS7671) referred to in the Building Regulations.

The batteries supplied with this fitting are a 

consumable part and therefore may be outside of 

any warranty offered. 

INSTALLATION:

 

DANGER! 

Please note that there are two live 

supplies, one switched and one permanent; please 

ensure you isolate both before you undertake any 

work on the emergency fitting.

 

01)  Undo the screws at each end of the diffuser and 

lift off.

02)  Press the tabs protruding from the gear tray to 

open.

03)  Make the cable entry and fixing holes as required. 

Inside the back of the fitting, there are markings 

to assist you.

04)  Using the back of the fitting as a template, mark 

the position of the fixing holes on your mounting 

surface.

05) Make fixing holes and fit plugs as appropriate.

06)  Secure the back of the fitting to the mounting 

surface using suitable fixings (not supplied).

07)  Apply a silicon sealant to the fixings if moisture or 

weather-proofing is required.

08)  Fitting a cable gland will also be necessary if 

moisture or weather-proofing is required.

09)  Thread the supply cable through the entry point 

and into the fitting.

10)  Make connection to the mains supply according 

to the colour code below. Take care not to leave 

any strands protruding from the terminals and 

that the terminals clamp onto the bare wire and 

not onto the insulation.

 

N

 - Neutral (Blue/Black) 

 

L

 - Permanent Live (Brown/Red)

11) Mark the current date on the battery pack.

12) Connect the battery pack to the circuit board.

13) Close the gear tray and press back onto the clips.

14) Replace the diffuser and tighten securely.

15)  Restore the power supply. The LED should light to 

indicate correct charging.

MAINTAINED VERSION ONLY:

 if the link has been 

left in place, the fitting should also light. If you have 

connected a switch across the terminals, test the 

operation of your switch.

 

OPERATION CHECKS:

Periodic testing should be carried out to ensure 

emergency lighting is operating correctly. 

Interruption of the supply, causing the fitting to be 

energised from the battery, should be carried out by 

the operation of a local keyswitch or other isolation 

device. During this period all fittings should be 

examined visually to ensure that they are functioning 

correctly. At the end of the test period the supply 

shall be restored and all indicator lamps or devices 

checked to ensure that the normal supply has been 

restored. 

DAILY:

 

Visual inspection of the battery charge LED.

EACH MONTH:

 

Isolate the power supply for a period sufficient to 

ensure that each lamp is illuminated. Endorse the 

test record form supplied.

ONCE EACH YEAR:

 

Isolate the power supply and check that the light is 

still illuminated after 3 hours. Endorse the test record 

form.

Because of the possibility of a failure of the normal 

lighting supply occurring shortly after a period of 

testing of the emergency lighting system or during 

the subsequent recharge period, all full duration 

tests shall wherever possible be undertaken 

preceding time of low risk to allow for battery 

recharge.

 

NOTE: please keep this instruction booklet and 

the test record in a safe place. A fire officer or 

other authorised person may want to see your 

record of inspection and testing.

SPECIFICATIONS:

• Power: Non Maintained: 3W / Maintained: 5W

•  Continuous illumination: >3 hours in emergency 

operation

• Battery: 3.6V Ni-Cad, 3 x C cells 1500mAh

• Recharge time: 24 hours

• Over-discharge protection: Yes
 

IMPORTANT NOTES:

The control gear must be operated only within the 

enclosure supplied. The gear must not be operated 

outside of the enclosure.

When energised by a constant mains supply, the 

battery will be constantly charged whether or not 

the lamp is illuminated. On failure of the constant 

mains supply, the fitting will switch automatically 

using transistorised switching from battery charging 

to battery discharge powering the lamp whether 

or not the lamp was illuminated before the power 

failure.

 

LAMP REPLACEMENT:

 

 

 

DANGER!

NOTE:

 this unit has a  permanent live mains supply, 

please ensure you isolate before removing cover.

There may also be a seperate switched supply that 

controls the emergency light fitting - this also needs 

to be isolated.

MAINTAINED MODEL ONLY:

NOTE:

 To convert the maintained fitting to non-

maintained operation, remove the link between 

terminals “L” and “LI”.

 

NOTE:

 If the lamp is to be switched, remove the link 

from between the terminals “L” and “LI” and connect 

cable from your switch into ‘LI’.

The light source contained in this luminaire 

shall only be replaced by the manufacturer, 

service agent or a similar qualified person. 

CAUTION, RISK OF ELECTRIC SHOCK.

The light source is designed to last the lifetime of the 

luminaire.