Pack Contents: 

Flush fitting complete with PIR Detector  x 1 
TC-DD 28W Lamp x 1

Содержание CF28PIR

Страница 1: ... CF28PIR Flush Ceiling Fitting with Integral PIR Detector IMPORTANT Please read these instructions before installing your new fitting Please retain for future reference Pack Contents Flush fitting complete with PIR Detector x 1 TC DD 28W Lamp x 1 ...

Страница 2: ...masonry It is not suitable for use on highly flammable surfaces e g polystyrene textiles Before making fixing hole s check that there are no obstructions hidden beneath the mounting surface such as pipes or cables The chosen location of your new fitting should allow for the product to be securely mounted e g to a ceiling joist and safely connected to the mains supply lighting circuit If the location ...

Страница 3: ...ore effective than movement directly toward or away from the sensor If movement is made walking directly towards or away from the sensor and not across the apparent detection range will be substantially reduced Installation 1 Choose the location for your new fitting according to each of the conditions above 2 Turn out the three clips at the side of the diffuser and lift off 3 Remove the tube from t...

Страница 4: ...4 Installation Instructions and Care 3 5m 120º 2 5m 360º 6m 12m 360º 12m 3 5m 120º 2 5m 360º 6m 12m 360º 12m Installation Diagram Sense Range Diagram 3 5m 120º 2 5m 360º 6m 12m Lux Time Diagram ...

Страница 5: ...n the lamp switches on release the Lux control You may need to make further adjustments to achieve your ideal light level setting Important To avoid dust build up and ensure proper functioning of the PIR detector periodically wipe the sensor lens lightly with a damp cloth Specification Voltage 220 240 V 50 Hz Load Max 28W CFL Detection Range Approx 120º horizontal Max 8 meters Duration Time From 8 ...

Страница 6: ...ith your retailer or local authority for suitable options New regulations require the recycling of Waste from Electrical and Electronic Equipment European WEEE Directive effective August 2005 UK WEEE Regulations effective 2nd January 2007 Environment Agency Registered Producer WEE GA0248QZ Safety Markings Cleaning Disconnect the power and clean the exterior only of this fitting with a moist not wet...