IR1759-MK5-AT3130-EDCONT MINIRAY
TE Connectivity - Aerospace, Defence & Marine
/// Application Tooling
Page
35
of
36
The controller is switched on from the Mini-ray Hand-tool trigger maintaining operation while the
trigger is pressed. Once the trigger is released, or the maximum operating period of 70 seconds is
reached, the controller will automatically switch to a TIME OUT mode indicated by the green ‘ON’
LED going off. Further action of the Hand-tool is inhibited until the TIMEOUT period of 2 seconds as
lapsed. This process is programmed by the four switches shown below and in (fig 2 page 32). To
accesses this you need to remove the four screws in the top cover of the controller, Check the
switches are in the set position shown and not been re-sett.
Fig A
9. Contact
TE/Tyco Electronics UK Ltd
Faraday Road,
Dorcan,
Swindon,
Post Code – SN3 5HH
Telephone: +44 (0) 1793 528 171
FAX: +44 (0) 1793 572 516
Website: http://www.te.com/usa-en/product-CV3948-000.ht