Cleaning
Front Reflector and Outer Filter Face Cleaning –
Heat from the lamp is directed by the reflectors and is concentrated in the heating zone in the front
reflector.
Contamination of the reflectors or the filter will decrease the efficiently of the tool. Therefore, they
should be periodically inspected for cleanliness. Normally, only the front reflector and the outer face
of the lamp filter will need cleaning. The rear reflector and inner face of the lamp filter are protected
from the work area, so contamination is less likely. Contaminated surface should be cleaned with a
soft cloth and isopropyl alcohol.
Fan and Housing Cleaning –
Since the lamp draws large quantities of air through the tool, dirt and lint may accumulate in the fan
area and gradually restrict the air flow. Therefore, this part of the tool should be inspected
occasionally and cleaned, when necessary with a soft brush. To facilitate cleaning, simply remove the
mounting screws located on the rear of the fan cover.
During Each Quarter –
Check and clean fan and housing
Front filter and outer face cleaning
Check any damage to tool and front reflectors
6.2 Gun Maintenance