Feedthrough Relay Panel Relay Kit

Feedthrough Relay Panel Relay Kit

Page 4 of 5

ETC

4. If installing one relay remove only one slot from the relay voltage barrier.

5. Install the relay into the relay slot.

a. From the center of the Relay Panel, direct the relay under the voltage barrier and into the slot.

b. Align the input terminal side with the mounting bracket.

c. Press the output terminal side down into the mounting clip until secure.

CAUTION:

Be careful not to damage the relay control board or connectors during relay installation.

1) Break the tabs off using pliers.
2) Bend the barrier back and forth until free.

a

c

b

Low voltage wiring harness 
provided in the relay kit

Side view detail

Relay 
voltage 
barrier