background image

Copyright © 2011. Electronic Theatre Controls, Inc.

All Rights reserved.

Product information and specifications subject to change.

Part Number: 

7065M1200

 Rev B

Released: 2011-11

User Manual

Production Dates: May 2011 - Present

Source Four XT HID Zoom 15° to 30°

Содержание Source Four XT HID Zoom 15-30

Страница 1: ...ic Theatre Controls Inc All Rights reserved Product information and specifications subject to change Part Number 7065M1200 Rev B Released 2011 11 User Manual Production Dates May 2011 Present Source Four XT HID Zoom 15 to 30 ...

Страница 2: ...pany names mentioned herein may be trademarks and or service marks of their respective owners This product is protected by one or more of the following U S Patents 6 016 038 6 150 774 6 788 011 6 806 659 6 683 423 and 7 023 543 Basic Assembly 1 Basic Information 1 Lamp and Ballast Information 2 Compliance Information 2 Replacing the HID Lamp 3 Installation 5 Electrical 5 Removing and Installing th...

Страница 3: ...use Do not use this fixture with a damaged power lead If the power lead cordset is damaged it must be replaced Do not mount the fixture on or near combustible surfaces Do not use this fixture if glass lens is deeply scratched or cracked Damaged lenses must be replaced Do not operate the fixture for long periods of time without the barrel installed Remove foam packing from internal lenses before co...

Страница 4: ... EN60598 1 EN60598 2 17 EN60922 EN55015 EN61000 3 2 EN61000 3 3 EN61547 CAUTION Do not use lamps other than the HID in Source Four XT fixtures Use of lamps other than HID will void UL cUL safety compliance and your warranty CAUTION This fixture must be grounded CAUTION The fixture is sold for either 120V or 220V 230V 50Hz 240V 277V to match the power supply Verify that the lamp and ballast voltage...

Страница 5: ...of the fixture Step 6 Carefully pull the old lamp out of the ceramic base Step 7 Holding it by the base remove the new HID lamp from its box WARNING Do not replace the lamp when it is raining or snowing Do not stand in water while replacing the lamp Failure to follow this warning can result in serious injury or death WARNING Disconnect power and let the lamp cool before replacing Note Verify that ...

Страница 6: ...de and not touching the lamp Step 11 Tighten the screws in a zig zag pattern CAUTION Use caution when installing or replacing any lamp When installing or replacing lamp be sure to point the lamp away from your face and away from others before inserting it firmly into the assembly This may prevent injuries if the lamp should break Note To avoid premature lamp failure do not touch the lamp glass If ...

Страница 7: ...lters and patterns Wind Load 1 4 cubic feet of effective projected area EPA Electrical The fixture is completely pre wired at the factory and there is no need for entry into the ballast housing WARNING Do not use this fixture with a damaged power lead If the power lead cordset is damaged it must be replaced Failure to follow this warning can result in serious injury or death WARNING All third part...

Страница 8: ...k Figure 5 Barrel Hanging Studs and Slots on Yoke Step 4 Use the safety loop and the optional safety cable to secure the barrel if needed To install the barrel Step 1 Slide the barrel down over the lens rails aligning the three ridges of the barrel with the ridges on the housing Step 2 With the barrel down as far as it will go rotate it until the internal locating pins go in the locating holes WAR...

Страница 9: ...e barrel It is recommended to partially tighten each screw working around the barrel until all are snug Tightening the screws draws the barrel down to the self sealing gasket Note The barrel will not seal properly until the internal locating pin goes through the locating hole Barrel locating holes ...

Страница 10: ...m Figure 7 Lens Arrangement Step 1 Remove the barrel as described in Removing and Installing the Barrel page 6 Step 2 Turn the Source Four XT on and aim it at a flat surface Step 3 Pull the shutters outward so that the aperture is fully open Refer to Adjusting Shutters page 11 Step 4 Loosen the two knurled thumb screws on the field lens holder WARNING Do not remove the barrel and expose the interi...

Страница 11: ... beam Step 6 Loosen the two knurled thumb screws on the focus lens holder Step 7 Gently slide the focus lens back and forth on the rails until you get the desired focus of the beam and then finger tighten the thumb screws Moving the lens towards the lamp sharpens the focus so that the edges are hard Moving the lens away from the lamp softens the focus so that the edges are soft Step 8 Shape the be...

Страница 12: ...tterns One pattern holder for steel patterns is supplied with the fixture Additional glass or steel pattern holders are available from ETC Figure 9 Pattern Holder Dimensions Step 1 Remove the barrel as described in Removing and Installing the Barrel page 6 Step 2 Insert the pattern into the pattern holder upside down and in reverse of the desired projection Note The projected beam is the inverse o...

Страница 13: ...ring shutter retention system You do not need to tighten or loosen the screws to make adjustments Step 1 Remove the barrel as described in Removing and Installing the Barrel page 6 Step 2 Turn the Source Four XT on and aim it at the structure you are illuminating Step 3 Pull the shutters outward so that the aperture is fully open Figure 11 Shutters and Their Tabs Step 4 Use the tabs on the shutter...

Страница 14: ... The standard yoke provides 45 to 40 when bracket or pole mounted The optional long yoke allows 90 to 35 fixture angle including straight up or down aiming Figure 12 Yoke Locking Screw Step 1 Using an 8mm hex wrench loosen the two yoke locking screws Do not remove them Step 2 Tilt the fixture to the desired position Step 3 Tighten the two yoke locking screws to secure in position Yoke locking scre...

Страница 15: ...ter or a 50 50 mixture of each can be used to clean the glass surface Step 4 If the reflector needs to be cleaned refer to Cleaning the reflector page 14 Step 5 Return the lenses to the required positions if needed Step 6 Replace the barrel WARNING Do not use ammonia based or other harsh commercial cleaners Clean lens and reflector only as directed Commercially available glass cleaning agents shou...

Страница 16: ...lamp during cleaning remove the lamp assembly Refer to Replacing the HID Lamp page 3 Step 1 Remove the barrel Refer to Removing and Installing the Barrel page 6 Step 2 Remove dust with a blast of oil free air or wipe with a clean lint free cloth Isopropyl alcohol distilled water or a 50 50 mixture of each can be used to clean the glass surface Step 3 Gently wipe the reflector Step 4 Reinstall the ...

Страница 17: ...15 ...

Страница 18: ...16 Source Four XT HID Zoom User Manual ...

Страница 19: ...17 ...

Страница 20: ...0 20 8752 8486 Holzkirchen DE Ohmstrasse 3 83607 Holzkirchen Germany Tel 49 80 24 47 00 0 Fax 49 80 24 47 00 3 00 Hong Kong Rm 1801 18 F Tower 1 Phase 1 Enterprise Square 9 Sheung Yuet Road Kowloon Bay Kowloon Hong Kong Tel 852 2799 1220 Fax 852 2799 9325 Service Americas service etcconnect com UK service etceurope com DE techserv hoki etcconnect com Asia service etcasia com Web www etcconnect com...