Error Codes
31
Error Codes
When you apply power to the fixture, it runs a calibration (homing) sequence and displays any
errors that it detects.
Example:
When the display shows "Error channel: Pan Coarse", it means there is an
error in channel 1. When multiple errors are present they will cycle on the display
twice, and then the fixture will reset (restart). Any errors that remain after two reset
cycles are not correctable by reset alone and will require service. Please contact
support if detailed assistance is needed.
This message displays after the reset of the fixture if any of the following conditions exist:
Pan
This message displays after the reset of the fixture if any of the following conditions exist:
•
the yoke’s magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Pan movement is not located in the default position after the reset
Tilt
This message displays after the reset of the fixture if any of the following conditions exist:
•
the fixture head magnetic-indexing circuit malfunctions (optical or magnetic sensor
failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Tilt movement is not located in the default position after the reset
Zoom
This message displays after the reset of the fixture if any of the following conditions exist:
•
the magnetic-indexing circuit malfunctions (optical or magnetic sensor failure)
•
the stepper motor is defective or the related IC driver on the main PCB has failed
•
the Zoom wheel is not located in the default position after the reset