ETC Installation Guide
ColorSource Spot jr v2.0/v3.0
Safety cable
attachment loop
Safety Cable
A safety cable (or other approved
safety device) must be attached to the
fixture. The attachment loop is on the
rear of the fixture. Leave as little slack
as possible in the safety cable to avoid
catching the yoke of the fixture.
Connectors
•
Power: Two powerCON
®
connectors for power in and thru
•
Data (DMX512/RDM): Two five-pin XLR connectors for data in and thru
Note:
The ColorSource Spot jr is not self terminating. You must
terminate the last fixture in line with a 120 Ohm resistor. To purchase
a terminator, please contact ETC customer service and request part
number SGE1507 (XLR terminator).
Set Up the Fixture
1. Plug the power cord into the powerCON In connector on the rear of the
fixture.
2. Make any power-thru cable connections prior to applying a power
source.
3. Make any DMX connections, and if the fixture is the last in a DMX line,
terminate the fixture. See
4. Plug the power cord into the power source.
Power Up
Press any button to wake the display. The display shows the DMX address.
See
.
You can press the Mode button to access the Presets/Sequences menu. See
Play Presets and Sequences on page 8
.
ColorSource Spot jr
Page 4 of 16
ETC