ETC ColorSource CYC v1.7 Скачать руководство пользователя страница 12

ETC Installation Guide

ColorSource CYC v1.7

Quick Reference

DMX Control Channels

DMX 

Channel

5ch

(5 channel)

dir

(Direct)

1ch

(1 Channel)

rgb

(RGB)

1

Intensity

Intensity

Intensity

Red

2

Red

Red

Green

3

Green

Green

Blue

4

Blue

Blue

5

Strobe*

Indigo

6

Lime

7

Strobe*

*Use DMX values of 0 or 255 for no strobe. Use values of 1–254 to increase the strobe rate

from 1 per second up to 33 per second.

Error Codes

There are three error codes that may be shown on the user interface.

CAL

: Screen toggles between

CAL

and

ERR

to indicate a problem with

the color calibration. The fixture will need to be returned to the ETC
factory; contact your local dealer to set up a repair.

OtP

: Screen toggles between

OtP

and

ERR

to indicate that the fixture

has gone into over-temperature protection mode to avoid damaging
the fixture. Once the fixture has self-cooled, the error will automatically
clear.

No App

: Screen toggles between

no

and

APP

to indicate that the

upgraded fixtures have a software issue. Reload software to clear the
error. If the error persists, contact ETC.

ColorSource CYC

Page 12 of 12

ETC

Содержание ColorSource CYC v1.7

Страница 1: ... etcconnect com ip 7415M2100 1 7 Rev C Released 2020 03 Overview The ColorSource CYC is an affordable LED fixture that uses the RGBI L red green blue indigo and lime color system to provide a rich bright light Note Features described in this document require the latest version of software For information on updating fixture software see Update the Fixture Software on page 9 Safety For professional...

Страница 2: ... cause an unsafe condition Do not use this equipment for other than intended use SAVE THESE INSTRUCTIONS Note The light source in this luminaire is not user replaceable and must be replaced only by a qualified technician Contact ETC Customer Support for assistance Environment The ColorSource CYC operates in ambient temperatures of 0 C 40 C The ColorSourceCYC is for indoor use only Maximum recommen...

Страница 3: ...Power Current Idle 1 66 W 0 04 A 1 38 W 0 04 A 1 18 W 0 05 A Direct at Full 133 7 W 1 34 A 132 6 W 1 11 A 130 4 W 0 59 A Safety cable anchor point Yoke locking knob Washer Installation Mounting The ColorSource CYC is designed for floor mounting You can also use the yoke accessory included for top hang pipe mounting with a clamp Use the included yoke locking knobs and washers see image at right to ...

Страница 4: ...xture 1 Plug the power cord into the powerCON In connector on the rear of the fixture 2 Make any power thru cable connections prior to applying a power source 3 Make any DMX connections and if the fixture is the last in a DMX line terminate the fixture See Connectors above 4 Position the fixtures appropriately Setback Minimum recommended distance from the cyclorama is 2 ft 61 m Spacing Position th...

Страница 5: ...for the fixture You can also use RDM for DMX addressing See RDM Values on page 10 Change the DMX Control Mode You can set the DMX control mode for the fixture to one of four available mode options 1 Press any button to wake the display The display shows the DMX address 2 Press and hold the Mode button for 3 seconds The display shows the current DMX control mode 3 Press the Up button or Down button...

Страница 6: ...t mode bypasses this calibration and multiple fixtures may produce slightly different outputs when controlled as a group DMX Control Channels DMX Channel 5ch 5 channel dir Direct 1ch 1 Channel rgb RGB 1 Intensity Intensity Intensity Red 2 Red Red Green 3 Green Green Blue 4 Blue Blue 5 Strobe Indigo 6 Lime 7 Strobe Use DMX values of 0 or 255 for no strobe Use values of 1 254 to increase the strobe ...

Страница 7: ...ton to activate the Presets Sequences menu The last active preset or sequence plays automatically If DMX data is present the current preset or sequence plays in the background and DMX data continues to take priority 2 Press the Up button or Down button as needed to scroll through the available presets and sequences 3 To stop the selected preset or sequence press the Mode button a second time The d...

Страница 8: ...resets When you re record presets with the fixture in RGB mode rgb the intensity is set to full and the strobe is turned off See Change the DMX Control Mode on page 5 Adjust the Intensity of Presets 1 Ensure that DMX data is not present 2 Press the Mode button to access the Presets Sequences menu and then press the Up button or Down button to select the preset that you want to edit 3 Press and hol...

Страница 9: ...ColorSource Spot jr fixtures ColorSource Spot jr fixtures can only update and be updated by other ColorSource Spot jr fixtures 1 Remove power and DMX In from the master fixture that is running the software version that you want to push to other fixtures 2 Press and hold the Up button and Down button simultaneously while restoring power 3 The display will show Udt rdy to indicate the update mode is...

Страница 10: ...perature protection mode to avoid damaging the fixture Once the fixture has self cooled the error will automatically clear No App Screen toggles between no and APP to indicate that the upgraded fixtures have a software issue Reload software to clear the error If the error persists contact ETC RDM Values Parameter Value Description Manufacturer ID 0x6574 Electronic Theatre Controls Model ID 0x0215 ...

Страница 11: ...ETC Installation Guide ColorSource CYC v1 7 ColorSource CYC Page 11 of 12 ETC ...

Страница 12: ... shown on the user interface CAL Screen toggles between CAL and ERR to indicate a problem with the color calibration The fixture will need to be returned to the ETC factory contact your local dealer to set up a repair OtP Screen toggles between OtP and ERR to indicate that the fixture has gone into over temperature protection mode to avoid damaging the fixture Once the fixture has self cooled the ...

Отзывы: