
Cobalt 8.1 - 20181029
1031
1.
A command Path.
This starts with a "/" and looks similar to a URL web address that you
would type into your browser.
Eg: /cobalt/param/pan/wheel
2.
Zero or more Values. (Sometimes called Parameters or Arguments)
Some OSC commands
have optional values, while others require one, two or even more values.
These are shown in
angle brackets, with the range if applicable:
Eg: <palette 1-999>
How do I use it?
OSC apps have various different ways to specify the OSC Path and the OSC Value (where
needed)
Be sure to check the manual for your OSC app to see how to type in the Path and the Values.
In many OSC applications, the values may be specified as a range. For example, an OSC fader will
need a Minimum and a Maximum value.
If you are having trouble, check with whether you've
entered the Path and the Value(s) for the command correctly for the software you are using.
TouchOSC:
TouchOSC always sends at least one value, set by the Value Range.
For example, the console [Go] button:
All Cobalt OSC commands also support the additional press (1.0)/release (0.0) value syntax used by
TouchOSC buttons.
To convert the normal OSC command into this format, move the Values into the
Path and use Value Range 0.0-1.0.
Example TouchOSC Buttons:
•
To send the OSC Command "/cobalt/playback/goto" with the value
3:
"/cobalt/playback/goto/3" with Value Range 0.0-1.0
•
To send the OSC Command "/cobalt/chan/at" with the value 75:
"/cobalt/chan/at/75" with
Value Range 0.0-1.0
•
To send the OSC Command "/cobalt/directselect" with the values 1, 2,
1:
"/cobalt/directselect/1/2/1" with Value Range 0.0-1.0
Example TouchOSC Fader:
•
To send the OSC Command "/cobalt/chan/at" with the values 0-100:
"/cobalt/chan/at" with
Value Range 0.0-100.0
This is what a GO key will look like in TouchOSC:
Содержание Cobalt 10
Страница 1: ...Part Number 4370M1200 8 1 0 Rev A Released 2018 11 Cobalt Family User Manual Version 8 1 0...
Страница 3: ...Cobalt 8 1 20181029 1...
Страница 113: ...Cobalt 8 1 20181029 111...
Страница 128: ...Cobalt 8 1 20181029 126 Misc Soft Key Page The Miscellaneous Soft Key Page is selected with the soft key MISC...
Страница 135: ...Cobalt 8 1 20181029 133 About Play This is a summary of your play The same information is included in your printouts...
Страница 170: ...Cobalt 8 1 20181029 168...
Страница 220: ...Cobalt 8 1 20181029 218 Key Backlighting in Cobalt...
Страница 221: ...Cobalt 8 1 20181029 219 Displays Lighting Congo Hardware console settings...
Страница 241: ...Cobalt 8 1 20181029 239...
Страница 263: ...Cobalt 8 1 20181029 261 High level of detail...
Страница 277: ...Cobalt 8 1 20181029 275...
Страница 329: ...Cobalt 8 1 20181029 327...
Страница 339: ...Cobalt 8 1 20181029 337 In the Times tab you can set fade and moving device times...
Страница 340: ...Cobalt 8 1 20181029 338 See Preset Times See Sequence Times See Moving Device Times...
Страница 345: ...Cobalt 8 1 20181029 343...
Страница 388: ...Cobalt 8 1 20181029 386...
Страница 412: ...Cobalt 8 1 20181029 410 This is the Chase Wizard...
Страница 416: ...Cobalt 8 1 20181029 414 In the Sequence List In the Organizer...
Страница 423: ...Cobalt 8 1 20181029 421...
Страница 426: ...Cobalt 8 1 20181029 424 In the sequence tab of every record dialogue to a master Hold RECORD and press master key...
Страница 427: ...Cobalt 8 1 20181029 425 In the Play Settings dialogue press SETUP...
Страница 435: ...Cobalt 8 1 20181029 433...
Страница 444: ...Cobalt 8 1 20181029 442 Delete Partial...
Страница 446: ...Cobalt 8 1 20181029 444...
Страница 457: ...Cobalt 8 1 20181029 455 NOTE Hold C FORMAT to reset the zoom factor...
Страница 494: ...Cobalt 8 1 20181029 492 2 Check the box Include Channel View in pool...
Страница 503: ...Cobalt 8 1 20181029 501...
Страница 526: ...Cobalt 8 1 20181029 524 NOTE PARK applies to the selected cells when an Attribute View is open...
Страница 538: ...Cobalt 8 1 20181029 536 Example Data in Excel easy to import...
Страница 549: ...Cobalt 8 1 20181029 547 A console button will require that you choose the button in a dropdown...
Страница 604: ...Cobalt 8 1 20181029 602...
Страница 620: ...Cobalt 8 1 20181029 618 4 Press DELETE A popup will appear for confirmation 5 Press MODIFY to confirm...
Страница 689: ...Cobalt 8 1 20181029 687...
Страница 692: ...Cobalt 8 1 20181029 690 3 Done You can now control the effect See Select Activate Effects...
Страница 814: ...Cobalt 8 1 20181029 812...
Страница 817: ...Cobalt 8 1 20181029 815...
Страница 826: ...Cobalt 8 1 20181029 824...
Страница 832: ...Cobalt 8 1 20181029 830...
Страница 842: ...Cobalt 8 1 20181029 840...
Страница 878: ...Cobalt 8 1 20181029 876...
Страница 883: ...Cobalt 8 1 20181029 881...
Страница 1018: ...Cobalt 8 1 20181029 1016...
Страница 1075: ...Cobalt 8 1 20181029 1073 Utilities 188 Visualizer 991 WAF Alert Times 388 Welcome Screen 193 Workflow 56 X keys 1001...