ArcSystem Installation Manual
Installing 100–277 V Emergency Multi-Cell Luminaires
Instructions for installing 100–277 V emergency luminaires are below. See
Multi-Cell Luminaires on page 32
for instructions on installing 100–277 V standard luminaires.
Two-cell
luminaire
Four-cell
square luminaire
Four-cell
linear luminaire
Eight-cell
luminaire
A
C
B
C
B
A
A
A
C
B
D
C
B
D
A wiring compartment
B conduit entry for 1/2 in conduit
C DMX in and thru
D knockout for 1/2 in conduit
With the exception of power input terminations, ArcSystem 100–277 V emergency system
installation requirements are the same as those of ArcSystem 100–277 V non-emergency
systems. Complete the installation as follows, referencing these sections for installation details:
1.
Complete the steps of
Installing 100–277 V Multi-Cell Luminaires on page 32
.
2.
Install conduit hardware at the knockout or second hole in the side of the wiring
compartment.
Note:
Use flexible metal conduit when installing and focusing 277 V emergency
multi-cell luminaires.