background image

1.  Change  Mode

 

2.  Change Intensity

 

3.  Change Use Time

 

4.  Change 

Thermal Function

 

 

5. Change the Pad 

in Use

 

When you want to change the mode of the pad you are using, touch the pad 

button that you are using and touch mode buttons. Then the power stops. 

Reselect the mode and then adjust intensity with the dial to operate the product.

The product operates only for the use time remaining. If you want to add more

use time, you can change it by touching the time button.

When you want to adjust the intensity of the pad, touch the pad selection 

button and adjust it by turning the dial to the right or left. 

If you touch the time adjustment button, it flickers and you can set the 

desired time.

When you change the time, is adjusted to the same time for all pads in use.

You can change the thermal function of the abdomen pad (or Kegel pad)

and foot pad to OFF or ON by touching the thermal button during use.

If you want to change pads in use, you can just change the pad button in the

case of mounted pads. If you stop during use, press the pad selection button.

The operation stops.

Checklist after Use

1. Does the light of the LED and buttons turn off when you power off the display part?

2. Has the power cord been disconnected from the outlet?

Check list before Use

1. Is the power cord connected to the outlet normally?

Change During Use

6. Product Storage and Management Method

Self-inspection

5. How to Use

Содержание EEB-181

Страница 1: ...EMS Body Massager EEB 181 ...

Страница 2: ...llation Product Installation How to Use Display Part Diagram How to Use Each Function Wearing Method by Pad and How to Use Them Product Storage and Management Self inspection Storage and Management Method Repair Service and Product Warranty Error Message during Use Checklist before Repair Service Application About Repair Service Specifications 01 02 03 04 05 06 07 08 09 Certificate of Quality ...

Страница 3: ...ain According to a study whenTENS is applied the pain signals delivered to the brain are blocked and signal messengers such as endorphins are emitted to activate the pain suppression mechanism in the body In other words the product has a pad electrode contacted to the feet or skin and various forms of current and pulses flow through the pad electrode The stimulation by current or pulse massages mu...

Страница 4: ...need separate power 5 Effective Use Method For effective use it is important to contact the correct parts with the pad electrode Appropriate intensity and use times should be adjusted according to symptoms Stimulating one part continuously for more than 30 minutes and stimulating twice or more a day are not recommended Effects vary depending on the user s muscle tension and the necessary intensity...

Страница 5: ...t equipment e g 1 m The low frequency power becomes unstable 1 Pregnant women or cancer patients are recommended not to use the product 2 Do not use the product on the brain vicinity of heart eyes around ears upper neck inside of mouth reproductive organs or parts with skin diseases 3 Do not have a person who cannot express an opinion or a person who cannot operate the product use the product 4 Do...

Страница 6: ...ace touching the pad 11 When the power goes out switch off the product immediately Prohibited Caution 2 Cautions for Safety 01 A person who is receiving medical treatment or feels an abnormality in the body 02 A person who has a heart or cerebral nerve abnormality 03 A person who has acute diseases 04 A person who has a malignant tumor 05 A person who has high fever or body temperature of 38 06 A ...

Страница 7: ...s The thermal function 40 3 of the abdomen pad foot pad and Kegel pad helps the promotion of metabolism and enhancement of circulation and blood circulation is improved based on increases body temperature with the thermal function and low frequency muscle exercise and pumping work using the contraction relaxation of muscles Comfortable Use and Operation You can use it easily as you can understand ...

Страница 8: ...ause button Then it pauses temporarily and automatically powers off if you do not use it again in 20 minutes Separately Sold Pads are Also Available Pads that are sold separately can also be connected and used Examples Knee Pad Shoulder Pad Kegel Pad 3 Product Introduction and Description Strengths of Product ...

Страница 9: ... Acute Pain Ease of acute inflammation and pain control by gate control theory Knee abdomen thigh shoulder vertical muscles multi purpose feet Chronic Pain Ease of chronic inflammation and pain control by ascending pain theory Knee abdomen thigh shoulder vertical muscles multi purpose feet Muscle Contraction Blood vessel pumping effect caused by increase in muscle strength and muscle contraction A...

Страница 10: ...the pads can hang on Foot Pad Assembly Youcanusethiswhenyouassembleitwiththemainbodyandstand Pad Hangers This is used for hanging pads that are used frequently Stand Lower Assembling Bracket This is used when you assemble the stand and foot pad assembly Adaptor This is used when you connect power Abdomen Pad You can use it on the abdomen Abdomen Pad Band This is used when you fix the abdomen pad o...

Страница 11: ... a self adhesive pad consumable Self adhesive Gel Pad for Shoulder Pad Separately Sold This is a consumable so you should repurchase it if the adhesive power gets weak Kegel Pad Separately Sold Ultrasound Probe You can use this for cosmetic purposes or in painful areas and the probe should be moved in a circular way during use 2 Kinds of Cables for Pad Connection 1 ForThigh Pad 9 Pin 2 ForVertical...

Страница 12: ...tor Cover MainBody Pad Hanger Stand Power Connector Foot Pad UltrasoundElement 1 Abdomen Pad 1 Description of Basic Composition of Pad Conductive Rubber Far infrared Ceramic Abdomen Pad Cable 3 Product Introduction and Description ...

Страница 13: ...cal Muscle Pad 4 Multipurpose Pad 5 Foot Pad 6 Ultrasound Probe Ultrasound Element Conductive Rubber Conductive Rubber Conductive Rubber Conductive Rubber Conductive Rubber Conductive Stainless Steel 3 Product Introduction and Description ...

Страница 14: ...ofSeparatelySoldPads 1 Knee Pad 2 Shoulder Pad 3 Kegel Pad Conductive Rubber Self adhesive Pad Conductive Rubber Pad Cable Self adhesive Gel Pad Pad Cable LEFT RIGHT Ultrasound Element Pad Cable 3 Product Introduction and Description ...

Страница 15: ...swithascrewdriver Insert two fixing clips into the cable and tighten the two screws into the front stand with a screwdriver Take main body and components out of the accessory box 3 Assemble the Main Body Put the main body on the front stand and tighten the three screws with a screwdriver Connect the cable of the main body and the cable of the front stand using the connector Stand Lower Assembling ...

Страница 16: ...ws with a screwdriver Put the rear stand into the slot of the bottom of the foot pad assembly by tilting it and fit into the front stand tightly After tightening the screws engage the covers in the three screw tightening slots on the rear stand Engagethethickcoveronthetopofthestandfollowedby theremainingtwocoversinthemiddleandatthebottom Main Body Rear Stand Screw Stand Upper Lid Stand Middle Lid ...

Страница 17: ...How to Wear Band with Pads Connect pad band and self adhesive gel pad as shown below 1 AbdomenPad 2 VerticalMusclePad 5 How to Use ...

Страница 18: ...How to Wear Band with Pads 3 ThighPad 4 KneePad 5 Should Pad Self adhesive Gel Pad 5 How to Use ...

Страница 19: ...rubber to facilitate frequency conduction to rubber Fix the vertical muscle pad to the body tightly with the band Thigh Pad Spread dedicated media gel wet tissue etc evenly on the con ductive silicone rubber to facilitate frequency conduction to rubber Fix the vertical muscle pad to the body tightly with the band Foot Pad Sit on a chair and put your feet on the product as shown in the figure Be su...

Страница 20: ...as On all the time Display ofThermal Function Status Mode Selection Button number changes whenever Mode button is pressed Display of Selected Mode by Pad Intensity Adjustment Dial Display of Intensity by Pad UseTime Adjustment Button time is changed by 5 minute units Display ofTime Remaining Ultrasound Probe On Off Button 1 Put the product on a flat stable place 2 Check if the power matches the da...

Страница 21: ...and multipurpose pad 3 Select the Pad to be Used Touch the pad button that you will use now among the connected pads and then numbers flicker on the mode and intensity display 4 SelectMode As the numbers change whenever you touch the mode button you can touch it till the number you want appears As the available modes differ by pad you should select the set and displayed mode or the mode you want T...

Страница 22: ... unified as the one first set 7 Time Setting You can pause during use and the pause button flickers till you press the pause restart button again The product automatically powers off with the sound of a buzzer if you do not touch it again for 20 minutes 8 Pause Play 9 Power Off If you touch the power button during operation the power turns off with a sound 10 Select theUltrasound Probe Select the ...

Страница 23: ...left If you touch the time adjustment button it flickers and you can set the desired time When you change the time is adjusted to the same time for all pads in use You can change the thermal function of the abdomen pad or Kegel pad and foot pad to OFF or ON by touching the thermal button during use If you want to change pads in use you can just change the pad button in the case of mounted pads If ...

Страница 24: ...pingoffwithadryclothagain 3 Becarefultopreventwaterfrompenetratingintothemainbody 4 Afteruse poweroffandpulloutthepowercabletorestoretothestatebeforeuse Cleanthesurfaceofthe productandstoreitinadrystate 5 Donotbendapowercableorpadcableforcedlyorchangetheirformarbitrarily Itcancauseashortcircuit 6 Forstorageplace followthecautionsbelow Donotstoreinawetplace Storeinaplacefreefromthenegativeeffectsof...

Страница 25: ...d If you contact the customer consultation room after checking the error messages we will respond to you promptly Display Error Message during Use 7 Repair Service and Product Warranty 1H 2H 7H isplay Display Description Abdomen Pad High Temperature Error Kegel PadTemperature Error Foot Pad HighTemperature Error ...

Страница 26: ...able is connected as normal You can t you feel anything from the pad Make sure the connections between the pad and pad cable and between the pad cable and main body connector are normal Do you feel a tingling sensation on your skin Press the pad completely onto the skin When the pad is smeared with foreign substances wipe off the foreign substances with a dry towel or cloth Wipe off the skin and p...

Страница 27: ...requency is low Did you press your feet completely into the pad Was the power intensity of the low medium frequencyset to be low Was the pad pressed into the desired skin area Is the jack of the pad connected well Is the contact terminal between the pad and cable smeared with foreign substances Pads are overlapped and attached The contact surface of the pad is dirty The intensity is weak The power...

Страница 28: ... customer s fault or natural disasters a service fee is charged even during the free warranty period ResponsibilityforChargedService Customerspaythecost When a failure occurs due to natural disasters fire earthquake flood lightning etc When a failure occurs due to the customer s fault When a failure occurs because users used the product outside the warranty range for the product When a failure occ...

Страница 29: ...ower AC 100 240V 50 60Hz Power Consumption 60VA Maximum Output Current 1 0 A Maximum OutputVoltage 80Vp p Output Frequency 1Hz 4000Hz Operation Time Basic setting 30mins 5 60mins Setting Mode 1 8 digital program ThermalTemperature 40 3 Size 790 x 420 mm Weight Main Body 15Kg ...

Страница 30: ...ive free service Please store it carefully 1 The quality guarantee benefits of this product can be provided as written on the Certificate of Quality 2 As the free warranty period is calculated from the date of purchase be sure to record the purchase day When the purchase date is not confirmed the free warranty period is calculated from the manufacturing date 3 When customers use this home product ...

Страница 31: ......

Страница 32: ...www etbu co kr ...

Отзывы: