background image

ES5321.1 PWM I/O Board (48/32-CH)

User’s Guide

Содержание ES5321.1

Страница 1: ...ES5321 1 PWM I O Board 48 32 CH User s Guide...

Страница 2: ...t or single license Using and copying is only allowed in concurrence with the specifications stipulated in the contract Under no circumstances may any part of this document be copied reproduced transm...

Страница 3: ...ns on the Product 14 1 3 1 CE Mark 14 1 3 2 RoHS Conformity 14 1 3 3 KC Marking 15 1 4 Product Return and Recycling 15 1 5 Declarable Substances 15 1 6 About this Manual 16 1 6 1 Working with this Man...

Страница 4: ...3 2 Output Modes for the Output Signals 28 3 3 Multi Pulse Signals 28 3 4 SENT Signals 28 4 Connections and Connectors 29 4 1 Backplane Connector CO200 29 4 2 I O Connector CO9000 31 5 Technical Data...

Страница 5: ...48 channels Generating signals with frequencies up to 100 kHz on up to 32 channels Generating multi pulse signals with up to eight different period lengths and duty cycles on up to four channels Gener...

Страница 6: ...surement High Time s Low Time s Additive pulse width measurement Additive High Time s Additive Low Time s Frequency measurement Duty cycle measurement Duty Cycle L L H Duty Cycle H L H Level measureme...

Страница 7: ...Every one of the 32 outputs is implemented as push pull circuit one high side and one low side driver each per channel The output voltage level is predefined at I O connector CO9000 by one of the exte...

Страница 8: ...O Board 48 32 CH User s Guide 8 Introduction ETAS Fig 1 3 shows the block diagram of an output channel Fig 1 3 Block diagram of an output channel Out_Ref_1 Out_Ref_2 Out_CH0 Out_GND Strom berwachung S...

Страница 9: ...ges resulting from improper handling unintended use or non observance of the safety precautions 1 2 3 Requirements for Users and Duties for Operators The product may be assembled operated and maintain...

Страница 10: ...e ES5300 1 B Housing and not as a Stand alone unit The intended use of the ES5321 1 in an ES5300 1 A Housing or ES5300 1 B Housing is Use in industrial lab facilities or at industrial workplaces Use a...

Страница 11: ...egulations concerning work safety Power Supply The product is powered by the ES5300 1 A Housing or the ES5300 1 B Housing via the PCIe backplane connector The electrical connection is made via the bac...

Страница 12: ...le for the currents voltages and temperatures which occur and must be flame retardant in accordance with one of the following standards IEC60332 1 2 IEC60332 2 2 UL2556 UL1581VW 1 WARNING This is clas...

Страница 13: ...Off switch at the rear and unplug the power plug When plugging in connectors ensure that they are inserted straight and no pins are bent Maintenance The product does not require maintenance Repairs I...

Страница 14: ...mity for the product is available upon request 1 3 2 RoHS Conformity European Union The EU guideline 2011 65 EU limits the use of certain dangerous materials for electric and electronic devices RoHS c...

Страница 15: ...hat the devices are recycled in a resource friendly way that does not represent any risk to personal health and the environment Fig 1 4 WEEE symbol The WEEE symbol on the product or its packaging iden...

Страница 16: ...presentation looks as follows Target definition Any preliminary information 1 Step 1 Any explanation for step 1 2 Step 2 Any explanation for step 2 Any concluding comments Specific example Creating a...

Страница 17: ...ndows dialog win dows fields and similar are set in quota tion marks Select the setup exe file Text in selection lists program code as well as path and file names are displayed in Courier font A conve...

Страница 18: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 18 Introduction ETAS...

Страница 19: ...on page 21 Connecting Cable on page 22 LEDs on the ES5321 1 Backside on page 23 2 1 Scope of Supply You can find the scope of supply in chapter Ordering Information on page 38 2 2 ES5321 1 PWM I O Boa...

Страница 20: ...e secured with fuses 2 A In case of a fuse defect we recommend to send the board to ETAS for further testing For this purpose the device should be sent to ETAS see ETAS Contact Addresses on page 39 If...

Страница 21: ...ng is located in the manual for the ES5300 1 A Housing or the ES5300 1 B Housing Type Manufacturer Order no NANO2 Slo Blo fuse T 2 A 452 454 series Littlefuse 154 002 T CAUTION Do not install the ES53...

Страница 22: ...the ES5321 1 at a workplace that is protected against electrostatic dis charges CAUTION The air circulation inside the ES5300 1 A Housing or the ES5300 1 B Housing can be ensured only if all free slot...

Страница 23: ...Construction Installation and Fuses 2 7 LEDs on the ES5321 1 Backside There are LEDs on the backside of the ES5321 1 Their position is highlighted in Fig 2 3 and their meaning is explained in Tab 2 2...

Страница 24: ...put Error Lowside Off 0 No Error On 1 Error FP LED 3 Green Alle SENTIN NIOS 0 and NIOS 1 channels ready for SENTIN Messages Off 0 Error Blink 1 No Error LD1011 FP LED 4 Yellow Output Error Highside Of...

Страница 25: ...ignals on page 28 Multi Pulse Signals on page 28 SENT Signals on page 28 3 1 Supported Measuring Methods for Input Channels The following measuring methods exist for the 48 measuring inputs Measuring...

Страница 26: ...he ES5321 1 or the ES5321 2 Technical Data of the ES5436 1 Power Sources Tab 3 1 Technical data of the power sources When connecting the ES5436 1 observe the following note CAUTION Before connecting t...

Страница 27: ...Down using ES5321 for measurement and ES5436 1 as load simulation ES5321 VBAT DAC FPGA Level Detection Input_n ES5436 VBAT Chan_x VBAT_x X1 VBAT VBAT_x ECU VBAT ECU with Open Emitter Pull Down Configu...

Страница 28: ...ased on the SENT specification on up to 16 channels 3 3 Multi Pulse Signals A multi pulse signal consists of a sequence of several pulses with different fre quencies and duty cycles The multi pulse fu...

Страница 29: ...kplane Connector CO200 on page 29 I O Connector CO9000 on page 31 4 1 Backplane Connector CO200 Type ERNI ERMet ZD 4 pair angled female multipoint connector 4 12 order no 973099 Counterplug in ES5300...

Страница 30: ...eld GND GND GND GND 7 n c n c n c n c n c n c n c n c 7 shield GND GND GND GND 6 PCIE_JTAG_TDI PCIE_JTAG_TCK n c n c n c n c n c n c 6 shield GND GND GND GND 5 PCIE_JTAG_TMS PCIE_JTAG_TDO n c n c n c...

Страница 31: ...Erni Eurocard DIN 41612 Connector 5 Rows male Manufacturer ordercode 384299 Counterplug HARTING DIN 41612 Connector Manufacturer ordercode 02 05 000 0003 Crimp Contacts Harting Crimp Contacts Manufac...

Страница 32: ...nput_45 Input D 30 Input_36 Input_37 Input_38 Input_39 Input_40 Input D 29 Input_34 Input_35 UBATT_DIN_C UBATT_DIN_C UBATT_DIN_C Input C 28 Input_29 Input_30 Input_31 Input_32 Input_33 Input C 27 Inpu...

Страница 33: ...23 UBATT_DOUT_C UBATT_DOUT_C Output C 13 Output_16 Output_17 Output_18 Output_19 Output_20 Output C 12 REF_B_DOUT_C REF_B_DOUT_C REF_B_DOUT_C REF_B_DOUT_C REF_B_DOUT_C Output C 11 REF_A_DOUT_C REF_A_D...

Страница 34: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 34 Connections and Connectors ETAS...

Страница 35: ...Duty cycle 0 100 Duty cycle resolution 0 1 Accuracy in range of 1 Hz to 10 kHz 0 04 Accuracy in range of 10 kHz to 100 kHz 0 4 Resolution 8 ns 125 MHz Counter 31 bit Pulse width 120 ns to 17 s 231 1...

Страница 36: ...0 100 mA Frequency range 1 Hz 100 kHz Duty cycle 0 100 Accuracy in range of 1 Hz 10 kHz 0 04 Accuracy in range of 10 kHz 100 kHz 0 4 Accuracy of duty cycle duty cycle 50 of 1 Hz 10 kHz 0 2 Accuracy of...

Страница 37: ...ve humidity 0 to 95 non condensing Environment Use only inside enclosed and dry rooms Max contamination level 2 Temperature during operation 5 C to 40 C 41 F to 104 F Relative humidity 0 to 95 non con...

Страница 38: ...on This chapter features the ordering information for the ES5321 1 PWM I O Board 48 32 CH as follows Tab 6 1 Ordering Information for ES5321 1 Order Name Short Name Order Number ES5321 1 PWM I O Board...

Страница 39: ...Support For details of your local sales office as well as your local technical support team and product hotlines take a look at the ETAS website Borsigstra e 24 Phone 49 711 3423 0 70469 Stuttgart Fa...

Страница 40: ...ES5321 1 PWM I O Board 48 32 CH User s Guide 40 ETAS Contact Addresses ETAS...

Страница 41: ...Connectors 29 Construction 19 D Declarable Substances 15 Devices Connecting 13 E Electrical Safety 11 ETAS Contact Addresses 39 F Fuses 19 20 G Galvanically Isolated 32 33 I I O Connector CO9000 31 I...

Страница 42: ...pean Union 14 S Safety at work 10 Safety notices identification of 9 Safety precautions 9 Scope of Supply 19 SENT signals 28 Signals 25 Standards 37 Standards and norms 37 Supported measuring methods...

Отзывы: