vacuum cleaner can be switched on or off by pushing button
A4
marked with
the symbol "
I
I
" (Fig. 10). When control light
A8
is on, it signals that the vacuum
cleaner is in operation. The suction power can be adjusted with the control on hose
handle
C2
(Fig. 11) or by setting regulation
A6
(Fig. 10). The minimum suction power is
recommended for fine fabrics (e.g. curtains, drapes). The maximum suction power is
recommended for floor coverings (e.g. heavy-duty carpets). After finishing work, switch off
the vacuum cleaner and unplug it from the power supply. By switching button
A5
with
symbol " " (Fig. 10) the power cord will be wound automatically. The vacuum cleaner
can be held and carried by handle
A9
.
Full dust filter signaling
If the coloured field is displayed permanently on the indicator
A7
(Fig. 12) while the floor
nozzle is lifted above the cleaned surface at
the maximum suction power
, the dust filter
must be replaced.
Disregard changes on the indicator during vacuuming.
Dust filter replacement
Push lid
A3
of the vacuum cleaner
A2
(Fig. 13) by pushing lock
A3
. Hold handle
A15
with
the dust filter and remove it by pulling it (Fig. 14). Remove adapter
B
from guide ribs
(Fig. 15). By lifting off blocking lock
B1
, dust filter
A16
will be released from the adapter
(Fig. 16). Dispose of the dust filter with common municipal waste. Slide the projections on
the head of the new dust filter into the holes in the adapter and secure the head by slight
pushing (you will hear a snapping sound). Check proper fastening of the carton front by
slight pulling of the dust filter. Slide the adapter into the holder and then put the holder
back to the suction space of the vacuum cleaner. Close the lid of the vacuum cleaner by
snapping it.
Replacing micro-filters
After replacing about 5 dust filters, micro-filters must be cleaned or replaced with new
ones. Dispose of the used dust filter and the micro-filters with common municipal waste.
You can buy replacement filters and micro-filters in electro shop chain.
Suction micro-filter
Take out the grid with HEPA filter
A17
by pulling it (Fig. 17). Clean the HEPA filter in
running lukewarm water, e.g. using a cloth or a soft brush and let it dry completely
(Fig. 20). When it is dry, put the HEPA filter back to the suction space of the vacuum
cleaner to the maximum position.
Exhaust micro-filter
Take out exhaust grid
A12
from the vacuum cleaner by pulling it upwards (Fig. 18). Bend
the grid wall by pushing its the internal wall so that you can release blocking and then take
out cover
A13
(Fig. 19). Take out micro-filter
A14
. Clean the micro-filter in running
lukewarm water e.g. using a cloth or a soft brush and let it dry completely (Fig. 20). After
drying, insert the micro-filter back to the grid in the opposite direction and secure it with
a cover (you will hear a snapping sound). Insert the projections on the back cover into two
holes in the vacuum cleaner cover and snap the cover.
22
GB
Содержание Violeta
Страница 2: ...2 1...
Страница 3: ...3 5 2 4 3 6 7 9 8 12 11 10...
Страница 4: ...4 19 13 14 20 21 15 16 17 18...
Страница 40: ...o o eta 1483 I o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o 40...
Страница 41: ...o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o o IV V 41...
Страница 44: ...5 HEPA A17 17 HEPA 20 HEPA A12 18 A13 19 14 20 21 44 HEPA o o o o o o o o o 2...
Страница 45: ...V 300 3 o o o o o o o o VI I I I I 45...
Страница 54: ...eta 1483 54...
Страница 55: ...IV V 55...
Страница 58: ...HEPA A17 17 HEPA 20 HEPA A12 18 A13 19 A14 20 21 V 300 58 HEPA HEPA HEPA HEPA 2 HEPA...
Страница 59: ...3 VI I I I I HEPA HEPA 50 VII 59...
Страница 61: ...61...