Start-up
Open fuel chamber door
The draught fan must be running before the fuel
chamber door is opened so that any combustion gas
can be extracted from the fuel chamber.
1
Fuel chamber door
2
Ignition door
3
Combustion chamber door
If the boiler has not safely cooled, no boiler doors
may be opened without an operating draught fan.
A sudden inflow of air in the presence of smouldering
wood may result in an explosion.
The fuel chamber door is always closed during
both start-up and heating operation. It is opened
only when ash is removed from the boiler.
Check fuel chamber
Use the poker to distribute ashes and charcoal evenly
throughout the fuel chamber. In the panels, the two
upper openings for primary air must be free.
Also, the 3 burn-through openings in the grate must
stay open so that the fire reaches the combustion
chamber during ignition.
Place logs close together in fuel chamber
Add the required amount of closely spaced logs to the
fuel chamber. Stack the logs instead of throwing them
in at random. Always place the first layer of logs
lengthwise.
1
Half-metre logs
2
33 cm logs
Adjust log over burn-through opening
Lift the bottom log above the burn-through opening
with the poker and place pieces of charcoal (from the
fuel chamber) or small pieces of wood under it so that
the burn-through openings in the grate remain clear. To
Содержание TWIN 20 kW
Страница 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Страница 39: ...ETAtouch controller TWIN function block 39 ...
Страница 49: ...ETAtouch controller Buffer function block 49 ...
Страница 53: ...ETAtouch controller Hot water tank function block 53 ...
Страница 57: ...ETAtouch controller Fresh water module function block 57 ...
Страница 81: ......
Страница 82: ...www eta co at ...
Страница 83: ......
Страница 84: ...www eta co at ...