![eta TWIN 20 kW Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/eta/twin-20-kw/twin-20-kw_operation_2430478017.webp)
Start-up
17
8
Start-up
Check heating system's water pressure
In buildings with up to three storeys, the optimum
water pressure in a cold heating system is
between 1 and 2 bar.
For a warm heating system, the optimum water
pressure is between 1.5 and 2.5 bar.
If the water pressure is too low, fill the cold heating
system to approx. 2 bar. Do not fill to a higher
pressure, as water expands with increasing
temperature and the water pressure also rises when
the boiler is heating. The safety valve triggers at
approx. 2.8 bar.
Open heating lines
If the system is new or has been out of operation for
some time, verify whether the return riser mixing valve
is in the "AUTO" position and all shut-off valves in the
heating lines are open.
Always keep ball valves completely open to avoid
ruining the seals. Open valves by turning anti-
clockwise, and then turn back 1/4 turn from the fully
open position to relieve pressure on the valve stem.
Check buffer charging status
Before starting the boiler, check the current buffer
charging status to avoid adding too much wood.
The table on page
16
shows how much wood should
be added. The buffer charging status is shown in the
boiler overview.
Pay particular attention to the different energy
densities of the fuels and the lower heat
consumption in summer.
Open insulation door, draught fan starts automati-
cally
When the insulating door is opened, the draught fan
starts automatically and the switch changes to the
setting. The operating condition changes
from [Ready] to [Insulation door open]. The open
insulation door is shown on the display.
If the draught fan does not start, there is either a
fault or an alarm. Therefore check the messages
on the screen.
Содержание TWIN 20 kW
Страница 1: ...2016 04 02 EN 0000000302 V 001 X 36 0 2303 93412 001 TWIN pellet burner 20 26 kW Operation ...
Страница 39: ...ETAtouch controller TWIN function block 39 ...
Страница 49: ...ETAtouch controller Buffer function block 49 ...
Страница 53: ...ETAtouch controller Hot water tank function block 53 ...
Страница 57: ...ETAtouch controller Fresh water module function block 57 ...
Страница 81: ......
Страница 82: ...www eta co at ...
Страница 83: ......
Страница 84: ...www eta co at ...