18
www.eta.co.at
2500 h / annually
Cleaning and maintenance
Tar deposits can have several causes, for
example:
•
leak air through the heat exchanger cover, the
combustion chamber door or the lambda probe.
•
an incorrectly calibrated lambda probe
•
overly moist wood chips
•
insufficient boiler runtime (start-stop operation)
Check heat exchanger cleaner
Remove the cover for the heat exchanger cleaner
drive.
Fig. 2-28: Cover
Manually operate the lever and check its ease of
movement. Lubricate the spring, guide and bearing
with a heat-resistant lubricant.
Fig. 2-29: Lever
Check the gap between the sensor and the spring arm.
It must be 2 mm.
Fig. 2-30: Position sensor
Finally, re-attach the cover to the boiler.
Check seal on heat exchanger cover
Inspect the integrity of the seal on the heat exchanger
cover and replace if necessary.
Fig. 2-31: Heat exchanger cover