Cleaning and maintenance
Maintenance (expert)
39
Remove the cover on the top
Carefully remove the cover from the top.
Fig. 2-101: Cover
Cleaning the fill level sensor
Mark the correct installation position of the
mounting panel for the fill level sensor, e.g. with a
pen.
Fig. 2-102: Marking the installation position
Remove the filling level sensor mounting panel.
Fig. 2-103: Mounting panel for fill level sensor
Check the seal on the bottom of the mounting panel
and replace if necessary. Clean the fill level sensor
with a soft cloth.
Fig. 2-104: Checking the seal, cleaning the fill level sensor
Cleaning the strainer in the pellet hopper
Manually clean the strainer in the pellet hopper by
wiping and tapping with your fingers.
Fig. 2-105: Strainer
A visual check of the strainer is difficult without
dismantling the top plate. Practical tip: take a
photo of the strainer through the fill level sensor
opening (with your mobile phone, for example). From
the pictures you will recognise which points of the
strainer need to be cleaned.