ETA-ECS6RM
Electrical Control Sequencer
Страница 1: ...Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 ETA ECS6RM Electrical Control Sequencer ETA ECS6RM Electrical Control Sequencer ...
Страница 2: ...neck Lamp 11 ETA 15SH Standalone 15A Electrical Control Module 12 ETA 20SH Standalone 20A Electrical Control Module 14 ECM RACEWY ECM Raceway Housing 14 ECM 3BP Raceway Blank Plate 15 ETA ECM20M Electrical Control Module 15 ETA ECM20 Electrical Control Module Without Current Monitoring 15 ECS KSW6 Remote Key Switch and Monitor 16 ETA ECS6RM Configurations 17 ETA ECM20 ETA ECM20M Wiring Configurati...
Страница 3: ...ry from tip over 13 Unplug this device during lightning storms or when unused for long periods of time 14 Refer all servicing to qualified service personnel Servicing is required when the device has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled objects have fallen into the device the device has been exposed to rain or moisture does not operate normall...
Страница 4: ... result in electric shock or fire Do not place any metallic objects or containers with liquid on the top of the device If any liquid spills into the unit fire or electric shock may result Never operate this device or touch the power supply cord during an electrical storm electric shock may result Never exceed the wattage on the product when connecting equipment Fire and or property damage may resu...
Страница 5: ...n be placed up to 1000 ft away from each other Each ECM module has an input DC voltage trigger of 5VDC plus three low voltage data port connections for AC Mains monitoring If AC outlets are required to be placed within the same rack as the ETA ECS6RM the ECM RACEWY6 raceway can house up to six ETA ECM20 or ETA ECM20M modules and six independent 20A AC 120V lines For remote locations where single o...
Страница 6: ...Auto On Off switch Incoming AC present LED Active LED AC Fault LED Clamping Spike Surge Suppression EVS Circuitry AC Mains Voltage Current monitoring Voltage only for ETA ECM20 EMI RFI Filtering Not in ETA ECM20 APPLICATIONS The ETA ECS6RM was designed to be flexible with features that allow it to be used in a variety of applications The sequenced outputs allow the turning of equipment On and Off ...
Страница 7: ...Bi Color LEDs that represent Channels 1 thru 6 of the ETA ECS6RM These LEDs indicate when there is AC voltage present or if there is an error within the AC Mains System Red Standby If a Channel on an ETA ECM20 ETA ECM20M ETA 15SH or ETA 20SH module is connected to the ETA ECS6RM a Red LED will illuminate indicating that Channel is active and in Standby mode If there are Channels of the ETA ECS6RM ...
Страница 8: ...ing to function an ETA ECM20M ETA 15SH or an ETA 20SH module must be connected Also a minimum of 500mA of current draw must be at the ECM module for the ETA ECS6RM to read Less than that the display will read nA When using the ETA ECM20 module the Current display will read nA because it has no current sensing circuitry Note When first applying power to the ETA ECS6RM and no ECM modules are connect...
Страница 9: ... via the Remote Activation ports The others are via the Front Panel Activation Switch and ECS KSW6 Key Panel Switch 1 External Switch ExtSw The ETA ECS6RM can be remotely activated from hundreds of feet away A simple low voltage current single contact switch can be applied to the two terminal connections marked ExtSw on the Remote Activation port When these two points are shorted together the unit...
Страница 10: ... an ECM shutdown when an extreme voltage condition occurs and will auto reset when the voltage has stabilized When Disabled the EVS circuitry will trigger a shutdown during and extreme voltage condition and will not turn back on unless the unit is sequenced See EVS feature definition for details Note After changing a setting the unit power must be reset for the changed setting to take effect 5 Lig...
Страница 11: ...ression AC Spikes or Transients are commonly caused by utility power plant grid switchovers The amount of energy that can be injected into the power system can be immense with voltages reaching 6kV or amperage peaks of 3000A These spikes are very fast and usually only last for a very short period of time To protect against this potential problem incoming AC Mains have special suppression circuitry...
Страница 12: ...ming AC LED This LED will illuminate Red when the ECM has incoming AC power present at the module This LED must be On to operate Note If this LED is not illuminating check the following 1 The unit is plugged in 2 The AC Mains Breaker feeding the AC leg to the ECM module is Off 3 The internal fuse has been damaged This should only be inspected by an authorized technician 4 Active LED This LED will ...
Страница 13: ... ECM must be connected to the ETA ECS6RM controller to activate features such as AC Mains voltage monitoring load current monitoring and Extreme Voltage Shutdown EVS ETA 20SH Standalone 20A Power Conditioner and AC Spike Suppressor This Electrical Control Module ECM is a 20A Power Conditioner and AC Spike Suppressor designed to be a standalone Single Housing SH unit that can be placed up to 1000 f...
Страница 14: ... 6 ETA ECM20 ETA ECM20M Modules however it is ok to use less than 6 modules The open slot on the ECM RACEWY6 can be covered up using an ECM Module Blank Plate cover Two of these are included with the ECM RACEWY6 If not needed discard them If additional Blank Plates are required they can be purchased in packages of three ECM ACIN Wire Kit ETA offers a wire kit of stranded 12 guage UL wire for wirin...
Страница 15: ... current from the ETA ECM20M Module which could be in parallel with an ETA ECM20 Module which is on the same incoming AC line as the ETA ECM20M module They would have the same current reading because they are in parallel Also the EMI and RF filtering are across the same AC line leg so both ECM Modules connected to that line are filtered no need to have redundant filtering Note In this wiring confi...
Страница 16: ... 1 TO FROM ECM 20 STATUS SIGNAL D A V G TRIGGER VOLTAGE STATUS SIGNAL D A V G TRIGGER VOLTAGE STATUS SIGNAL D A V G TRIGGER VOLTAGE STATUS SIGNAL D A V G TRIGGER VOLTAGE 1601 Jack McKay Blvd Ennis TX 75119 www etasys com Engineered in the U S A Made in China External DC IN Trigger or External Contact Switch REMOTE CONTROL KEY PAD IN OUT SYSTEM CONTROL LAMP SYSTEM MASTER SLAVE1 SLAVE2 0 1 1 0 A A B...
Страница 17: ...LTAGE 1601 Jack McKay Blvd Ennis TX 75119 www etasys com Engineered in the U S A Made in China REMOTE CONTROL KEY PAD IN OUT SYSTEM CONTROL LAMP SYSTEM MASTER SLAVE1 SLAVE2 0 1 1 0 A A B C D E B 0 1 0 1 OFF ON NOTE AFTER CHANGING SWITCH SETTINGS THE UNIT S POWER MUST BE RESET 20V DC IN DELAY TIME 1 SEC 3 SEC 6 SEC 0 1 1 0 C D E E 0 1 ENABLE EVS DISABLE 0 1 CHANNEL RELAY CONTACTS REMOTE ACTIVATION ...
Страница 18: ... INCOMMING AC ETA ECM20 20A Sequencer Module AC 120V 60Hz 20A 2400W ACTIVE EXTERNAL TRIGGER MANUAL ON INCOMMING AC ETA ECM20 20A Sequencer Module AC 120V 60Hz 20A 2400W ACTIVE EXTERNAL TRIGGER MANUAL ON INCOMMING AC AC main in 20A 1 AC main in 20A 2 ETA ECM20 20A Sequencer Module AC 120V 60Hz 20A 2400W ACTIVE EXTERNAL TRIGGER MANUAL ON INCOMMING AC ETA ECM20 20A Sequencer Module AC 120V 60Hz 20A 2...
Страница 19: ...will need to be repaired or replaced It is important to have all equipment that was connected to that AC Mains Line be inspected for proper operation Note The unit will still operate but no AC Spike or Suppression protection will be available Issue 3 ECM module is set External Trigger the Incoming AC LED is Illuminated but the Active LED is not Illuminated Possible Cause 1 External DCV from the ET...
Страница 20: ...ossible Cause 2 Check Issues 1 4 first Possible Cause 3 Current Draw of ECM Module must exceed 500mA to register Possible Cause 4 Proper Channel is not selected for viewing Possible Cause 5 Channel Activation LED is Illuminated Green but the Current display reads nA Check the wiring between the ETA ECS6RM Channel and the ECM module V A and D must be in the correct polarity Issue 8 Not All Channel ...
Страница 21: ... LED Per Channel Total Six LEDs Activation Indicators Six Bi Color LEDs One For Each Channel Rear Panel Sequenced Activation Status Signal Port Six Channels Interconnect port Trigger Out and Status Signal Return Euro Phoenix Type Connector Remote Activation Trigger 5 24VDC Continuous 10 mA Switch Contacts Euro Phoenix type Connector Sequenced Relay Contacts Six Channels Single Relay Contact SPST E...
Страница 22: ... 22 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 NOTES ETA ECS6RM Electrical Control Sequencer ...
Страница 23: ... 23 ETAsys com Specifications are subject to change without notice 1601 Jack McKay Blvd Ennis Texas 75119 U S A Telephone 800 321 6699 Fax 800 996 3821 NOTES ETA ECS6RM Electrical Control Sequencer ...
Страница 24: ...When products returned to ETA Systems do not qualify for repair or replacement under our warranty repairs may be performed at prevailing costs for material and labor unless there is included with the returned product s a written request for an estimate of repair costs before any non warranty work is performed In the event of replacement or upon completion of repairs return shipment will be made wi...